Enter the text that appears when all areas sharing the 
same account number are master armed. The ACCT 
IS ON text appears at all keypads assigned to these 
areas, if more than one area has the same account 
number. The ACCT IS ON text also appears if only 
one area in the system is used. Refer to the prompts 
CC# Area Assign and Area # Acct Is On in Section 
 
2.10.2 Area Text 
Use this programming category to create custom Idle 
Text displays for the keypads. 
 
 
Each display can be programmed with up 
to sixteen alphanumeric characters, 
including: A to Z, 0 to 9,  ?,  &, @,  -,  *,  
 
+,  $,  #,  _,  /. 
Characters not listed are invalid and 
cannot be used for text. 
2.10.1 Keypad (Command Center) Assignment on 
page 51. When all areas in the account are master 
armed, the Area # Is On text is replaced by the ACCT 
IS ON text if the area is armed before all other areas 
with the same account number. 
Area 
Blank Entry 
Default: 
A blank entry disables the ACCT IS ON display for 
this area. An account wide area shows the AREA # IS 
ON text instead of the ACCT IS ON text. 
Selection:  1 to 8 
Enter the area number you are programming. 
Unique ACCT IS ON Text 
Area# Is On 
Each area can have unique ACCT IS ON text, or you 
can program the same text in each area of the 
account so when all the areas in the account are 
armed, they all show the same text. 
Default: 
Refer to the program record sheet 
Selection:  Sixteen alphanumeric characters 
D1260 Alpha V Keypad 
Enter the text for this area that appears when the area 
is master armed or master instant armed and other 
areas sharing the same account number are not yet 
master armed. This display does not appear when the 
area is perimeter armed. 
Although it is not programmed in this area, the D1260 
Alpha V Keypad can display up to sixteen characters 
for an Area Name on line 1 of its display. The Area 
Text (Area # Is OffArea # Not ReadyArea # Is On
and Acct # Is On) programmed in this module 
appears on line 2 of the D1260 Alpha V Keypad. 
When programming custom text, it should be logical 
to users viewing it on the D1260. For example, the 
Area Name Text can be programmed to display Front 
Office and the Area # Is Off text (programmed in this 
section) could be programmed to display Ready To 
Arm. The D1260 would then show on line 1 Front 
Office and on line 2, Ready To Arm. 
Area# Not Ready 
Default: 
Refer to the program record sheet 
Selection:  Sixteen alphanumeric characters 
Enter the text for this area that displays when the area 
is disarmed but points are faulted. 
Area# Is Off 
2.10.3 Custom Function 
Default: 
Refer to the program record sheet 
Use custom functions to simplify complex keystroke 
sequences entered at the keypad. These items are 
similar to speed dialing on a telephone. When the 
custom function appears on the keypad, a user can 
execute a request by pressing [ENTER]. You can 
have up to sixteen custom functions and restrict their 
use by area and authority level. 
Selection:  Sixteen alphanumeric characters 
Enter the text for this area that displays when the area 
is disarmed and no points are faulted. 
Area# Acct Is On 
Each Custom Function ### item has sixteen 
characters of programmable text (CF### Text). When 
the Custom Function is assigned to the menu M## 
Function
 (refer to Section 
Default: 
Refer to the program record sheet 
Selection: 
Sixteen alphanumeric characters 
77) the user can press [PREV] or [NEXT] to scroll to 
CF### Text. The user accesses the menu by 
pressing [MENU] on the keypad. 
The user needs the appropriate authority level 
enabled for the L## C Function 128 to 143 in Section 
2.11 User Interface
 on page 60, to use the custom 