Bosch Appliances Video Game Controller D9412GV2 Benutzerhandbuch

Seite von 158
D9412GV2/D7412GV2 | Program Entry Guide | 2.0  GV2MAIN 
EN | 62 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
 
 
Perim Partial 
View Memory 
Default: 
Default: 
Selection:  Blank, E, or P 
Selection:  Blank, E, or P 
 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Function Name 
Function 
No. 
Alternate 
Keystroke 
[COMMAND][8] 
Perimeter Partial 
Arm 
[COMMAND][4][0] 
View Event 
Memory 
Use this function to arm normal perimeter points and 
force-bypass faulted perimeter points, regardless of 
their P## Bypassable setting. When these force-
bypassed perimeter points return to normal, they 
automatically return to service, even if P## FA 
Returnable is set to No. 
Use this function to view prior alarm, trouble, and 
supervisory activity occurring since the last time the 
system armed. Event memory is not cleared until the 
area re-arms. 
View Pt Status 
Perimeter Partial arming has entry and exit delays. 
Default: 
 
 
Perim Partial ignores the A# FA Bypass 
Selection: 
Blank, E, or P 
Max entry in Section 2.9 Area 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
Parameters on page 36
 
10 
View Point Status  (Menu function 
only) 
 
Local Only Reporting: No Closing 
Report is sent to the central station, but a 
Use this function to view points assigned to the area 
where the keypad is assigned. This function shows 
point text and the electrical condition (normal, open, 
short, and missing) of each point in the area. 
Perimeter Delay Closing Event is 
 
generated in the event log. 
 
View Area Stat 
Walk Test 
Default: 
Default: 
Selection: 
Blank, E, or P 
Selection:  Blank, E, or P 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
View Area Status 
(Menu function 
only) 
11 Walk 
Test 
[COMMAND][4][4] 
Use this function to view the armed status of all areas 
within the scope of the keypad assigned to this area. 
The armed states include A# AREA # IS OFF 
(disarmed), A# AREA # IS ON (master delay armed), 
ALL ON INSTANT (master instant armed), and AREA 
# PERIM ON (perimeter instant armed or perimeter 
delay armed). All area types, master, associate, 
regular, and shared can be viewed using this function. 
Use this function to test Controlled points in areas 
within the keypad’s scope without sending reports to 
the central station. 24-hour points cannot be tested 
using this Walk Test Mode. 
Fire Test 
Default: 
Selection: 
Blank, E, or P 
 
Function Name 
Function 
No. 
Alternate 
Keystroke 
12 Fire 
Test 
[COMMAND][5][8] 
Use this function to test 24-hour points in areas within 
the scope of the keypad where the function is 
entered. Controlled points, P## Type 12, 3, cannot 
be tested using the Fire Walk Test Mode.