Bosch Appliances Radio LE10 Benutzerhandbuch

Seite von 24
LE10 Radio Receiver
Product information | en
7
Bosch Security Systems
User Manual
F.01U.278.517 | V2.0 | 2012.11
2.3
Main applications
LE10 Radio Receiver as small stand alone call system
After receiving a radio signal from a programmed radio 
transmitter, the relay output switches a siren or a lamp to 
indicate locally a wireless call.
LE10 Radio Receiver connected to a emergency call system 
via relay contact
After receiving a radio signal from a programmed radio 
transmitter, the relay will be switched. This relay output is 
connected to a wired emergency call system by wire and hereby 
a call will be generated or forwarded.
LE10 Radio Receiver as part of a Resident Alert System 
monitoring dementia
After receiving a signal from a dementia transmitter, the relay 
will be activated to close a monitored door.
2.4
Description of the different modes
Mode Name
Description
1
Normal
20 wireless transmitters can be programmed. 
Calls are indicated by the red LED and Relay 1. 
A battery-low signal is indicated by the red 
LED and Relay 2.
2
Normal, with red LED 
deactivated at 
battery-low indication
The same functions as in mode 1 are available, 
except for the battery-low signal which is not 
indicated by the red LED, but only by Relay 2.
3
Dementia
The MIYS37L and MIYS37E wireless 
transmitters are detected. Relay 1 can be used 
to lock a monitored door. Relay 2 can be used 
to interrupt a monitoring loop.