Bil-Jax Wheelchair XLB-4232 DC Benutzerhandbuch

Seite von 116
XLB-4232 DC 
 
3-2 
 
Lower Control Panel 
The lower control panel (Figure 3-2) is located on the side of the hydraulic power 
compartment. The following controls and indicators are on the lower control panel. 
 
Figure 3-2.   Lower Control Panel (DC Model) 
EMERGENCY  STOP  Pushbutton 
When pressed, the EMERGENCY  STOP pushbutton disconnects electrical power to the 
upper and lower control panels. The EMERGENCY  STOP pushbutton should only be 
pressed to immediately stop all boom motion. To resume control, pull to disengage the 
emergency stop switch contacts. 
BOOM  UP/DOWN  Selector Switch 
Holding the BOOM  UP/DOWN selector switch in the UP position enables the boom to 
rise. Holding the selector switch in the DOWN position enables the boom to descend.  
The up or down boom motion continues until the selector switch is released, or the boom 
reaches a hard stop or a safe travel limit. 
UPPER/OFF/LOWER  Controls Selector Switch 
The UPPER/OFF/LOWER controls selector switch enables boom lift control from either 
the lower control panel or the work platform.  When operating the boom lift from ground 
level, hold the switch in the LOWER position while simultaneously selecting a motion 
function.