Behringer high-precision digital 24-bit/96 kHz EQ/RTA mastering processor DEQ2496 Benutzerhandbuch

Seite von 23
20
ULTRACURVE PRO DEQ2496
7. SPECIFICATIONS
Digital inputs/outputs on optical connectors are also available.
5.4 WORDCLOCK connection
If several devices shall be embedded into a digital recording
system  comprising,  for  example,  a  digital  mixing  console,  all
connected digital devices must be synchronized using a common
wordclock  signal.  To  this  end,  your  DEQ2496  features  a
wordclock input, which can be used to control external equipment
via  wordclock  signals.  The  input  supports  the  sample  rates
44.1, 48, 88.2 and 96 kHz, and can be activated only if the analog
inputs are used.
6. OPERATING software
The operating software of your ULTRACURVE PRO DEQ2496
is  constantly  being  developed  to  improve  its  performance  and
adapt the operation of the unit to user requirements. We would
therefore be pleased to hear about your suggestions and ideas
for improvement. We will try to include your suggestions in the
next  software  revision.  Information  on  new  software  versions
are available from the trade press, your retailer, from our web
site  at  www.behringer.com  or  directly  from  BEHRINGER
(Tel. +49 2154 9206 4166).
The  current  software  revision  of  your  ULTRACURVE  PRO
DEQ2496 is displayed in the UTILITY menu on page 1 (top right).
7. SPECIFICATIONS
Analog  inputs
Type
electronically  balanced
Connector
XLR
Impedance
22 kΩ at 1 kHz
Max. input level
+12 or +22 dBu, switchable
CMRR
40 dB typ.
Analog  outputs  (main)
Type
servo-balanced
Connector
XLR
Impedance
100 Ω at 1 kHz
Max. output level
+12 or +22 dBu, switchable
Analog  outputs  (aux)
Type
servo-balanced
Connector
1/4" stereo jack
Impedance
100 Ω at 1 kHz
Max. output level
+12 dBu
System  specifications
Frequency  range
10 Hz to 35 kHz (-1 dB)
@ 96 kHz sampling rate
Signal-to-noise ratio
> 113 dB main input/output
> 107 dB aux output
THD
0.007 % typ. @ +4 dBu, 1 kHz,
unity gain
Crosstalk
< -92 dB/-95 dB
Bypass
Type
Relay,  hard-bypass in case of
power  failure
Measurement  microphone  input
Type
electronically  balanced
Input impedance
2 kΩ
Max. input level (LINE)
variable from -14 dBu to +22 dBu
Max. input level (MIC)
variable  from  -42  dBV/Pa  to
-6 dBV/Pa
Phantom  power
+15  V,  switchable
Digital input 1
Type
XLR  transformer-balanced
Standard
AES/EBU or S/PDIF
Input impedance
110 Ω
Nom. input level
0.2 - 5 V peak-to-peak
Digital input 2
Type
TOSLINK optical
Standard
AES/EBU or S/PDIF
Digital  output  1
Type
XLR  transformer-balanced
Standard
AES/EBU or S/PDIF
Impedance
110 Ω
Output level
3.5 V peak-to-peak
Digital  output  2
Type
TOSLINK optical
Standard
AES/EBU or S/PDIF
Sync  input
Type
BNC
Standard
Wordclock (1 x sample rate)
Input impedance
50 kΩ
Nom. level
2 - 6 V peak-to-peak
MIDI  interface
Type
5-pole DIN jacks In/Out/Thru
Implementation
cf. MIDI implementation chart
Digital  processing
Converter
24-bit Delta-Sigma,
64/128-oversampling  (AKM
®
)
Sample rate
44.1, 48, 88.2, 96 kHz
Graphic  equalizer  (GEQ)
Type
digital 1/3-oct EQ
Frequency  range
20 Hz to 20 kHz, 31 1/3-oct. bands
according to ISO frequencies
Bandwidth
1/3-oct.
Control range
+15 to -15 dB
Parametric  equalizer  (PEQ)
Type
max. 10 independent, fully
parametric filters per channel
Frequency  range
20 Hz to 20 kHz
Bandwidth
1/10 to 10 oct., shelving filters
(6 and 12 dB)
Control range
+15 to -15 dB
Dynamic  equalizer  (DEQ)
Type
max. 3 independent, fully
parametric filters per channel
Frequency  range
20 Hz to 20 kHz
Bandwidth
1/10 to 10 oct., shelving filters
(6 and 12 dB)
Control range
+15 to -15 dB
Threshold
variable from 0 to -60 dB
Attack
0 to 200 msec
Release
20 to 4,000 msec
Ratio
1:2 to 1:100
Feedback  Destroyer  (FBD)
Type
digital signal analysis for
feedback  identification
Filter
max. 10 digital notch filters per
channel, programmable or as
automatic feedback suppression
system
Frequency  range
20 Hz to 20 kHz
Bandwidth
1/10 to 1/60 oct.
Control range
0 to -60 dB