Beckett AQUASMART 7600WTM Benutzerhandbuch

Seite von 12
2
Wireless communication
10+ year battery life
Up to 200 ft. range from 
boiler
Wireless module and 
outdoor sensor are 
linked together out of 
the box.
Simple installation - no 
wiring
Warm weather shutdown
Features
Table of Contents
Features ...................................................................
2
Technical Specifi cations ........................................
2
Electrical Ratings ..............................................
2
Environmental Ratings ......................................
2
Approvals ..........................................................
3
Operation .................................................................
4
Installation ...............................................................
5
Initial Set-up ......................................................
5
Replacing the WTS battery ...............................
7
Installing a new AWM or WTS ..........................
7
Navigating the Display Menus ...............................
8
Programming Basic Functions ..............................
9
OTR ON/OFF: ...................................................
9
High OAT: ..........................................................
9
Low OAT: ...........................................................
9
Boost: ................................................................
9
Programming Additional Options..........................
9
Heat Manager Effi ciency Setting: .....................
9
Warm Weather Shut Down (WWSD): ...............
9
Other Menu Items .................................................
10
Current Outdoor Air Temperature (OAT): .......
10
Signal Strength: .............................................
10
Current WTS Battery Life: ..............................
10
Adding Connections: ......................................
10
Clearing Connections: ...................................
10
Broadcast Once: ............................................
10
Limited Warranty Information .............................
12
Technical Specifi cations
Electrical Ratings
AquaSmart Wireless Module:
Voltage:
 5 Vdc +/- 4% (from AquaSmart COM 
port)
Current:
 45 mA max (from AquaSmart COM 
port)
Line Power: 
300 mW max (in addition to 
AquaSmart’s power consumption)
Wireless Temperature Sensor Battery 
Specifi cations:
Product will not function using 
a standard 1.5V AA Battery.  Do 
not use the included battery in other devices.
3.6V, lithium, AA, button top, primary (non-
rechargeable) battery
Recommended replacement batteries
LS14500 (Saft), TL-5903 (Tadiran)
Do not return used or damaged batteries to the 
manufacturer.  Disposal of spent batteries should 
be performed by an authorized, professional 
disposal company, which has knowledge in the 
requirements of the Federal, the State and the 
Local authorities regarding hazardous materials, 
transportation and waste disposal.  Contact your 
local EPA offi ce if unsure of how to dispose of 
batteries properly.
Environmental Ratings
Storage and operating ambient temp.
: -40 °F 
to +150 °F (-40 °C to +65.6 °C)
Moisture
:
AquaSmart Wireless Module: 5 to 95% RH, non-
condensing and non-crystallizing.
Wireless Temperature Sensor: 5 to 95% RH, 
condensing.  Weatherproof.  Not submersible.
a.
b.
Risk of Fire, Explosion, and Burn 
Hazard.
This control must be installed, adjusted 
and put into operation only by a trained, 
licensed, qualifi ed professional or 
service agency.
Call RWB Technical Services at 1(800)645-2876 for 
assistance.
y
NOTICE