Windsor 10080480 Benutzerhandbuch

Seite von 69
MAINTENANCE-PERIODIC 
 86292100 CLIPPER DUO 10/02/07 
4-3  
 
PERIODIC  MAINTENANCE 
 
Twice a month, flush a white vinegar solution (One 
quart vinegar to two gallons of water) or anti-
browning solution (mixed as directed) through the 
extractor. This will prevent build-up of alkaline 
residue in the system. If spray jets become clogged, 
remove the spray tips, wash them thoroughly, and 
blow-dry. 
 
NOTE: Do not use pins, wire, etc. to clean 
nozzles as this could destroy spray pattern

 
Periodically inspect all hoses, electrical cables and 
connections on your machine. Frayed or cracked 
hoses should be repaired or replaced to eliminate 
vacuum or solution pressure loss. If the cable 
insulation is broken or frayed, repair or replace it 
immediately. Don’t take chances with electrical fire 
or shock. 
 
DAILY / REGULAR  MAINTENANCE 
 
NOTE: Before making any adjustments or repairs 
to the machine, disconnect the power cord from 
electrical source. 
 
1. 
Empty unused cleaning solution from the 
solution tank. 
 
2. 
Flush pumping system with 4 or 7 liters of clean, 
hot water. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3. 
After each use, rinse tank with fresh water. 
Periodically inspect the recovery tank and 
decontaminate if necessary, using a Hospital 
Grade Virucide or a 1-10 bleach to water 
solution. Waste water should be disposed of 
properly. 
 
4. 
Check for and remove any lint or debris around 
vac shoe. 
 
5. 
Check spray jets for full spray pattern.  
 
6. 
Remove lint and dirt build-up from brush and 
housing. 
 
7. 
Check float and shut-off screen and clean as 
necessary.