Cleaning the Dehumidifier
Exterior
NOTE: Have an authorized service technician clean and service 
the interior coils of your product annually.
1. Turn off dehumidifier.
2. Dust front grille and side panels with a soft brush or the 
dusting attachment of your vacuum cleaner. 
Water Bucket
Every few weeks, rinse the inside of the water bucket with a mild 
detergent to avoid growth of mold, mildew and bacteria.
Water Level Float
The dehumidifier has an Empty/Adjust Bucket light and a water 
level float. The bucket must be properly aligned for the water 
level float and Empty/Adjust Bucket light to work. 
NOTE: Be sure float is snapped in place.
TROUBLESHOOTING 
Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.
Dehumidifier will not run
Is the dehumidifier turned on? Turn on dehumidifier.
Is the power cord plugged into a grounded 3 prong 
outlet? 
Plug into a grounded 3 prong outlet. See “Electrical 
Requirements.”
Has a household fuse blown, or has a circuit breaker 
tripped? 
Replace the fuse or reset the circuit breaker. If the 
problem continues, call an electrician. See “Electrical 
Requirements.”
Is bucket installed properly? Reinstall bucket so that it fits 
all the way into the dehumidifier.
Does bucket need to be emptied? Empty bucket.
Is water level float in place? Remove bucket. Make sure 
float is snapped in place. Reinstall bucket.
Ice forms on coils
Model AD25B dehumidifiers do not have an automatic 
deicer. 
See model and serial number label for model number. 
If ice forms on coils, unplug dehumidifier until ice melts and 
room temperature rises.
All models, except AD25B, have an automatic deicer that 
will shut off the compressor and allow the fan to run. 
This 
reduces the ice buildup on the coils. The compressor will 
cycle back on when the deicer senses the correct operating 
temperature.
Dehumidifier runs but does not dehumidify
Do you have model AD25D? Units with this model number 
have a deicer that will shut off the compressor and allow the 
fan to run. When the deicer senses the correct operating 
temperature, the compressor will cycle back on.
Do you have control type 2 or 3? Units with these control 
types have a deicer that will shut off the compressor and 
allow the fan to run. When the deicer senses the correct 
operating temperature, the compressor will cycle back on.
Do you have control type 3? If you have selected 
Continuous Run, the dehumidifier will run continuously. If the 
humidity level is low, little or no water may be collected.
The filter (on some models) is dirty or obstructed by 
debris. 
Clean the filter.
Air coming from dehumidifier is warm
Dehumidifier will put out warm air under normal operating 
conditions.
A. Water level float
B. Bucket 
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING