NORSEMAN™ 1500/2500 FuRNAcE
 
VGZ-018 / 0805.1
locAtiNg FURNAcE
NOTICE: Installation of this furnace must be done 
by a qualified heating equipment installer.
C A U T I O N :   F U R N A C E   U N I T S   A R E     
hEAvY  -  APPROXImATELY  450-550  LBS. 
mAkE  SURE YOU  hAvE  PROPER  EqUIP-
mENT  AND  OR  SUFFICIENT  mANPOwER TO   
PREvENT  INjURY whEN  DELIvERINg  AND   
LOCATINg FURNACE UNITS.
1.  The furnace must be placed on solid concrete or 
masonry floor. 
NOTE: To reduce weight during in-
stallation remove parts from inside the firebox. 
Additional weight reductions can be obtained 
by removing the fire brick. make note of position 
so they are returned to the same positions. 
CAUTION: DO NOT OPERATE ThIS APPLIANCE 
wITh CRACkED OR mISSINg FIREBRICkS.
2.  The  furnace  should  be  located  in  the  same 
room as the central heating system, as close as  
possible but no closer than 6˝ to the central system. 
(See figures 16 – 23)
3.  Obser ve  the  clearances  to  combustible  
materials as listed and shown in figures 1, 2 & 3.
minimum Clearances to Combustible Surfaces
Front: 48 in.   Side: 16 in.   Back: 26 in.
Chimney Connectors: 18 in.  Plenum to wall- 
studs, joists or finished wall or ceiling: 2 in.
4.  The furnace must have its own flue. 
DO NOT CON-
NECT ThIS UNIT TO A ChImNEY FLUE SERvINg 
OThER APPLIANCES.
5.  Install  furnace  pipe,  elbows,  and  thimble  as  
required,  utilizing  either  a  recently  cleaned  and 
inspected 6˝ masonry chimney or a 6˝ i.d. listed uL 
103 HT chimney. NOTE: A barometric draft regula-
tor may be necessary if the chimney draft is found 
to be excessive 
6.  u s e   6 ˝   r o u n d   bl a ck   f u r n a c e   p i p e,   n o t  
galvanized furnace pipe. Secure pipe sections with 
three (3) sheet metal screws in each furnace pipe 
and/or elbow joint to firmly hold the pipe sections 
together. 
7.  R e c h e ck   c l e a ra n c e s   f r o m   t h e   f u r n a c e,  
connector  furnace  pipe,  and  corner  clearanc-
es  using  the  illustrations  in  figures  1  –  3  and 
your  local  building  codes  or  fire  protection  
ordinances.  
 
NOTE:  A  studded  wall  faced  with  brick  or  stone 
should be considered a combustible surface.
8. 
DO NOT INSTALL ThIS FURNACE IN A mOBILE 
hOmE, mANUFACTURED hOmE, TENT OR TRAILER. 
NO EXCEPTIONS! 
(HUD Federal Standard: 24 CFR Ch.XX)
9.  The  clearances  provided  are  minimum  dimen-
sions  determined  by  the  manufacturer’s  test-
ing  facility  in  accordance  with  u.S. Test  Stan-
dard  uL  391.  Installation  of    this  furnace  must  
comply with the latest edition of NFPA 211 for re-
duced clearances and/or your local building code 
rulings  (use  whichever  minimum  dimensions  are 
LARGEST).
Fig. 1 – Top View   
Minimum Clearances from Combustible Surfaces
Fig. 2 – SiDe View   
Minimum Clearances from Combustible Surfaces