NOTE: Installation must be made by a qualified 
heating equipment installer (one who is engaged in, 
and is responsible for, or is thoroughly familiar with the 
installation and operation of gas, oil, and solid fuel burn-
ing heating appliances, who is experienced in such work 
and familiar with all the building requirements and/or fire 
codes of the authority having local jurisdiction.) 
This is a furnace, not a stove. Heated air must be 
directed  away  from  the  furnace  or  it  will  not  operate 
properly.
1.  T h e   i n s t a l l a t i o n   i s   t o   b e   c o m p l e t e d   i n  
accordance  with  National  Fire  Protection  
Association  (NFPA)  installation  standards  No. 
89M, 90B, 211, 70 (National Electrical code) and 
uniform Mechanical code 913, 6-4 in states where 
applicable  (where  code  offers  making  flue  pipe 
connections  into  an  existing  chimney  with  other 
fuel burning appliances).
2.  Wood/coal  burning  appliances  need  air  for 
combustion  and  circulation  to  the  house.  
Provision  must  be  made  to  provide  make  up 
air  so  as  not  to  starve  the  central  heating  
system  of  combustion  air.  Have  the  local  regu-
lating  authority  determine  that  make  up  air  
supply  is  adequate.  Reference  NFPA  standards 
No. 30 & 54, code for Installation of Gas and Oil 
Equipment.
3.  H ave   t h e   l o c a l   r e g u l a t i n g   a u t h o r i t y   o r  
qualified  exper t  inspect  all  chimneys  and  
installations  for  adequate  venting  and  for  
compliance  with  standard  local  codes  and  
regulations  regarding  installation  of  wood/coal 
burning appliances. (Also see Pipe Installation on 
following pages.)
4.  Position  the  fur nace  according  to  clear-
ances  shown  in  figures  1–3  and  to  maintain  
chimney connections as short as possible. Avoid 
unnecessary turns and installation of devices that 
would  create  excessive  resistance  to  the  flow  of 
flue gases.
5.  Make  flue  pipe  connections  to  the  chimney 
with  24-gauge  pipe  and  elbows  (not  included 
with  furnace)  maintaining  proper  clearances. 
Seal  the  flue  pipe  in  the  chimney  with  fur-
nace  cement.  (chimney  connections  must  be  
securely supported and joints fastened with sheet 
metal screws.)
FURNAcE iNstAllAtioN
6.  For parallel installations, install (two) 8˝ anti-back-
draft butterfly dampers (Vogelzang Model AD-8, 
not 
included with the furnace) in the heat (duct) pipes  
a  minimum  of  18  inches  above  the  furnace  
plenum. Anti-backdraft butterfly dampers may be 
obtained where you purchased your appliance or 
from a local HVAc distributor.
7.  Install  8˝  diameter  26-gauge  heat  (duct)  pipe 
and  connectors  (not  included  with  furnace)  to 
make  connection  to  the  plenum  of  the  central  
heating  system.  The  heat  pipe,  plenum,  and  
connections  must  be  constructed  of  metal  with 
a  minimum  temperature  rating  of  250°  F.  If  
central  air  conditioning  is  installed  in  the  
plenum,  install  heat  pipe  above  the  air  
conditioning  unit.  Secure  the  heat  pipe  
connection  with  supports  and  sheet  metal 
screws.
8.  Make  electrical  supply  connections  in  the  
electrical  junction  box  and  connect  power  
supply wires to designated wires using wire nuts 
(see wiring diagram figure 7 & 8). The power cord 
supplied may be used for installation if local codes 
and  regulations  permit.  If  not  permitted,  power 
supply  wiring  must  be  minimum  of  18-ga.  AWG 
copper and rated for 90° centigrade installed in a 
metal cable or conduit. Power connections should 
be  made  by  a  qualified  installer  to  comply  with 
NFPA  Standard  No.  70  and  all  local  codes  and 
regulations.