Siemens AC75 Benutzerhandbuch

Seite von 569
AC75 AT Command Set  
11.6 AT+CGDCONT
s
AC75_ATC_V01.002
Page 317 of 569
10/30/06
Confidential / Released
 
11.6
AT+CGDCONT Define PDP Context
Syntax
Command Description
The test command returns supported values as a compound value. 
The read command returns the current settings for each defined PDP context. 
The write command specifies the parameters for a PDP context identified by the context identifier 
. The
number of contexts that may be in a defined state at the same time is given by the range returned by the test
command. A special form of the write command (
) causes the values for context 
become undefined. 
Parameter Description
PDP Context Identifier
Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is
used in other PDP context-related commands. 
1...2
Packet Data Protocol type
Specifies the type of the packet data protocol.
“IP“
Internet Protocol (IETF STD 5)
Test Command
AT+CGDCONT=?
Response(s)
+CGDCONT: 
(range of supported
, , , (list of supporte
s)
OK
ERROR
+CME ERROR
Read Command
AT+CGDCONT?
Response(s)
[+CGDCONT: 
[+CGDCONT: ...]
OK
ERROR
+CME ERROR
Write Command
AT+CGDCONT=
[
[, 
[, 
[, 
[, 
[, 
]]]]]]
Response(s)
OK
ERROR
+CME ERROR
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
GSM 07.07
+
+
+
+
+
+
+
-
+
-
<cid>
(num)
<PDP_type>