AC75 AT Command Set  
22.2 ATS3
s
AC75_ATC_V01.002
Page 530 of 569
10/30/06
Confidential / Released
 
22.2
ATS3 Set command line termination character
Th
 command determines the character recognized by the TA to terminate an incoming command line. 
Syntax
Parameter Description
command line termination character
000...13
(&F)
...127
Notes
• Using a value other than the default 13 may cause problems when entering commands. 
• Whenever you change the setting take into account that the new value has no effect on the URC "
Read Command
ATS3?
Response(s)
OK
Write Command
ATS3=
Response(s)
OK
ERROR
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
V.250
-
+
+
+
+
+
+
-
+
-
<n>
(num)(&W)(&V)