Rinnai Corporation EX08C, EX11C Manual 
 
     CAUTION 
  Humidifier and Air Flow Direction 
 
 
 
 
 
 
 
 
 
 
 
 
 
Adjusting Air Flow Direction 
The vertical louvers may be adjusted to move the air 
flow more to the right or to the left.   
Use a screw driver or similar object to bend each 
louver to the desired position. 
Do not bend repeatedly (no more than 5 times) or else 
the louver will break. 
The horizontal louvers (which determines the vertical 
air flow direction) are fixed and cannot be adjusted. 
 
 Do not adjust the air flow 
louvers while warm air is 
flowing. 
Adding Water to the Humidifier 
Warm air is humidified when it passes over the water 
in the tray. 
To fill the tray, remove the bottom panel by pushing on 
both sides and pulling it toward you.  Pull the tray out 
and fill with water.  Do not exceed the fill line.  Push 
the tray back in and attach the bottom panel.  Do not 
operate the appliance unless the humidifier tray is 
installed. 
During operation a small amount of condensation is 
produced in the flue system and drains into the 
humidifier tray. 
     CAUTION 
 
Do not remove the bottom 
trim panel or the humidifier 
tray while warm air is 
flowing.   
  Set back 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This function allows a minimum room temperature to be pre-set, 
between 38ºF and 78ºF (in 2ºF increments).  This temperature 
should be set below the room temperature setting.  The default 
setting is 60ºF.  Once the Set back function is selected the appliance 
will start heating whenever the room temperature falls below the 
selected temperature, regardless of timer or manual settings. 
Follow these steps to set and operate the Set back feature: 
1.  Make sure the heater is turned OFF. 
2.  Press the “Set back” button.  The light above the button will 
come on.   
3.  Press the up and down buttons to set the minimum temperature. 
When the “Set back” indicator is on, frost protection is operating, 
and will always prevent the room temperature from falling below the 
pre-set minimum temperature (as long as electric power and gas is 
supplied). 
To turn this feature off, press the “Set back” button. 
The unit will retain its ON or OFF setting after a power failure. 