RGB Spectrum DGY 201 Benutzerhandbuch

Seite von 167
C O M M A N D   L I N E   I N T E R F A C E
Command Summary
350-8697
DGy Model 201 User Guide
121
. . . . .
RealTimeClockSYNC
<OFF | IRIG | 
NetworkTimeServer>
The internal DGy real time clock can be 
automatically synchronized to an external 
network time server. When the 
RealTimeClockSYNC is set to OFF, the DGy 
internal clock is not synchronized to an external 
time reference (IRIG or NTS). 
When the RealTimeClockSYNC is set to 
NetworkTimeServer the DGy will automatically 
synchronize it’s internal clock to the network time 
server specified by the NTSIP command. Note 
that when using the NTSIP to display your local 
time correctly, you must set the Time Zone to 
correspond with your geographical location.
Note: DGy requires a full time Internet connection 
to provide this capability. See also: NTSIP and 
TimeZone.
When the RealTimeClockSYNC is set to IRIG, the 
DGy will automatically synchronize it’s internal 
clock to the external (optional) IRIG time 
reference connected to the IRIG input (see also 
).
Factory default: OFF
RealTimeClockSYNCPERi
od
[30 ... 1440]
Sets the update interval period for the NTS or 
(optional) IRIG reference time servers. The period 
is set in minutes (30 to 1440 minutes).
Factory default: 120
Table 6-13.  
Time Commands