Panduit DPOE PN380C Benutzerhandbuch

Seite von 17
DP
O
E™ Power System User Manual 
 
Part Number: PN380C 
 
 
  
12
 
 
TROUBLESHOOTING 
 
The modular nature of this DP
O
E™ Power System makes diagnostics and repair easy. Make sure that all 
rectifiers are properly seated and latched into their respective slots. Make sure all power and signal 
connectors are properly mated.  
 
Table 8: Troubleshooting 
 
Alarm 
Problem 
Possible Solution 
DC OK LED is extinguished 
This rectifier has stopped 
outputting power 
Rectifier failed.  Replace this 
unit.  
AC OK and all LEDs are 
extinguished 
Commercial power has been 
lost to the specified rectifier(s) 
Reset commercial circuit 
breaker to the dedicated AC 
circuit that feeds the system.  
Seek alternative power source 
until power is restored. 
Fuse Open 
A fuse is in the open state 
Replace the open fuse