(8) Trigger 
(a) Set up by Administrator
(1) 
Go to “Trigger” in “Admin” menu by Control Panel.
(2) 
Select “Action” which you need when detecting the trigger signal (Trigger 1 to 8).
Trigger On or Off setting
Select  “Action” from the followings 
for the detection of trigger signals
“REC”
“STOP”
“AUTOZOOM”
“CAM1”
“CAM2”
“CAM1REC”
“CAM2REC”
“CAM1LED”: 
Change ON/OFF of
REC lamp on the Front Camera
(AG-CK10P) 
“NONE”:  No operation
Select the Detection from the followings and 
choice of detection depends on “Action”:
1.  In “REC”, “CAM1REC”, “CAM2REC” at Action,
Select the detection from 
“H”, “Level H”, “L”, “Level L”, “B”.
2.  In “CAM1”, “CAM2”, “CAM1LED”, “AUTOZOOM”, “STOP”,
Select the detection from 
“H”, “L”, “B”.
3.  In “None”, select the detection from 
H”, “L”, 
“SPEED” (Trigger 8 only)
Remark
:  
“SPEED” via speed pulse at Detection detects only in 
Trigger 8 since the detection circuit for the only Trigger 8 
is designed for speed pulse.
Assign the characters to be used in the OSD display.
*When SPEED is selected at the trigger, “Printable”
becomes ”-” and cannot be modified.  No OSD is displayed.