National Instruments NI Vision NI 17xx Benutzerhandbuch

Seite von 90
Chapter 4
Lighting
4-6
ni.com
The minimum voltage drop specified for the light does not fall below 
the specified range of the smart camera. Under some circumstances 
some LEDs, particularly certain lights with infrared LEDs and lights 
with only one LED per string, present a lower voltage drop than usual 
and may be incompatible with the smart camera. These lights may 
need to be reconfigured by the manufacturer to bring the voltage drop 
within the specified range of the smart camera.
Note
The voltage drop of a light can vary significantly with environmental conditions, 
such as ambient temperature, current supplied, and strobe time.
Refer to Appendix A, 
, for complete specifications for the 
Direct Drive lighting controller.
Connecting a Light to the Direct Drive Lighting Controller
This section applies only to the following NI Smart Cameras:
Figure 4-2 illustrates how to connect a light to the Direct Drive lighting 
controller. Do not use the GND signal when connecting a light to the Direct 
Drive lighting controller.
Figure 4-2.  Connecting a Light to the Direct Drive Lighting Controller
NI 1742
NI 1762
NI 1744
NI 1764
LED–
LED+
LED
NI 17xx
Direct
Drive