Technical Data (2)
Exposure Time
The equipment has one programmable timer with a non-volatile memory.
Preselection and setting
digital setting from 0.1 to 99.9 minutes
Setpoint value display
digital, 3 digits
Actual value display
digital, 3 digits; the remaining time is displayed,
i.e. after a mains failure exposure can be continued without any time error.
Prewarning Time
Preselection and setting
digital setting from 2 to 250 seconds or de-activated
Programmed Mode
Number of storable programs
250
Tube Parameters (Limit Data)
Number of memory locations
for tube parameters
for tube parameters
8
with digitally assigned tube limit data, e.g. nominal voltage,
limit filament current, anode power dissipation
Technology
20 kHz IGBT technology for high voltage circuit and filament current circuit
Emitted interference
as per EN 55011A, Class A
Immunity to interference
as per IEC 801-2/1991, 801-3/1984, 801-4/1988
Connected Loads and Mechanical Dimensions
Power connection
1/N~ 230 V ±10%, 50/60 Hz
Power consumption
4150 W at 60 kV, 58 mA
Max. mains current
24 A
Mains fuse
32 A (as per VDE)
Ground terminal
6 mm² Cu
Type of protection
as per EN 60529, IP00 (rack mount), IP32 (desk-top)
Cooling water connection
3/4 inch
Cooling water consumption
minimum 3.5 l/min, minimum 4.5 bar, maximum 7 bar,
at outlet point pressure-free
Cooling water temperature
> dew point < 25° C
Dimensions overall
483 mm x 266 mm x 680 mm (WxHxD), 19“ (48 cm) rack mount
Weight
approximately 57 kg
Specifications are subject to change without notice.