LXE VX6 Benutzerhandbuch

Seite von 380
32 Hardware 
Configuration 
VX6 Reference Guide 
E-EQ-VX6RG-J 
Power Supply 
Vehicle power input for the VX6 is 12V to 80V DC nominal and is accepted without the need to 
perform any manual operation within the VX6.   
If 12V to 60V DC power is not available – for example, in an office environment – an optional 
external Universal Input Power Supply can be used to convert AC wall power to an appropriate 
DC level. See “External Power Supply”, later in this chapter. 
Power input is fused for protection and the fuse is externally accessible. 
Uninterruptible Power Supply 
A DC uninterruptible power supply (UPS) battery is available to maintain power to the VX6 for a 
minimum of 15 minutes when vehicle power is not available (such as when a vehicle battery is 
being swapped). 
Backup Battery 
The LXE VX6 has a permanent lithium battery installed to maintain time and date.  The backup 
battery is not user serviceable and should last five years with normal use before it requires 
replacement.  
Note: 
This battery should only be changed by authorized service personnel. 
PCMCIA Slots 
Microsoft Windows CE Plug and Play operating system controls the PCMCIA cards.  These cards 
are hot swappable per the PCMCIA specifications. 
CF Slot 
The CF ATA slot is not hot swappable.  The VX6 must be powered down to insert or remove an 
ATA card.  Since the operating system is stored on the ATA card, the VX6 cannot operate 
without the ATA card.  
SD Slot 
The SD slot accepts an SD memory card.  These cards are hot swappable.