Ingersoll-Rand 7804 Benutzerhandbuch

Seite von 28
80181613_ed3
EN-1
EN
Product Safety Information
Intended Use:
These Drills are designed for driving fasteners and drilling.
For Additional information refer to Air Drills Product Safety Information Manual Form 04580353.
Manuals can be downloaded from www.irtools.com.
Product Specifications
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet.  Drain condensate from 
valve(s) at low point(s) of piping, air filter and compressor tank daily.  Install a properly sized Safety Air Fuse 
upstream of hose and use an anti-whip device across any hose coupling without internal shut-off, to prevent 
hose whipping if a hose fails or coupling disconnects. See drawing 16573180 and table on page 2.  
Maintenance frequency is shown in circular arrow and defined as h=hours, d=days, and m=months.  Items 
identified as: 
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled, degreased and parts 
be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
Model
Style
Free Speed
Chuck 
Capacity
Sound Level
(ANSI S5.1-1971)
Vibration Level
(ISO8662)
rpm
in (mm)
Pressure
Power
(ISO3744)
m/s
2
7804
Pistol
1800 @ 90 psi
1/4 (6.35)
83.6
94.6
0.3
1.
Air filter
7.
Coupling 
2.
Regulator
8.
Safety Air Fuse
3.
Lubricator
9.
Oil
4.
Emergency shut-off valve
10.
Grease - during assembly
5.
Hose diameter
11
Grease - through fitting
6.
Thread size