Hitachi Weather Radio EH-150 Benutzerhandbuch

Seite von 35
                                                              7. Collection of Temperate Data
7-2
7.2 Temperature Data
(1) Content of temperature conversion data [range : -50 to +400 
°
C] (Pt100/ Pt1000)
  The meaning of the each bit( b0 to b15) of temperature conversion data (in WX**) is as shown
below.
The sum of the bit “1” is the measured temperature.
   <For example>
(1) HF800  =“1111  1000  0000  0000"
                    (HF)  (H8)  (H0)  (H0)
   
    -800 + 400 + 200 + 100 + 50 = -50 
°
C
      (2) H0600   =“0000  0110  0000  0000"
                     (H0)  (H6)  (H0)  (H0)
   
     25 + 12.5 = 37.5 
°
C
When an input error occurs( below -51
°
C and over 410 
°
C), the temperature conversion data is
H7FFF.
The following relation exits between temperature conversion data and actual temperature.
 
Temperature (℃) =
         
Note) “b0” is always “0” in normal time.
Relation between the temperature and temperature conversion data
Figure 7.3
)Temperature conversion data(hexadecimal) -50 to +400 
°
C
H4000
H3000
H2000
H1000
H0800
-50
0
50
100
200
300
400
HF800
Temperate(
°
C)
b15 b14 b13 b12 b11 b10 b9 b8 b7
b5
b6
b4 b3 b2 b1 b0
(
°
C)
-800
400
200
100
50
25
12.5
6.25
3.125
1.563
0.781
0.391
0.195
0.0977
0.0488
0.0244
Note)
Temperature conversion data(signed decimal data)
40.96