Star Micronics TUP452-24 Benutzerhandbuch

Seite von 42
 
– 27 –
 
14.3 Allowable Static Electricity Level 
 
Notes)
 
 
Use SLS-060P-50 (Sanken) as the power source.
 
 
The reference data is shown in the table above; this data may differ depending on the installa-
tion conditions.
 
14.4 Vibration Test
14.5 Drop Test 
 
Quality control 
test specifications
Direct discharge
Element allowable level 
(self-printing)
 
±
 8 kV (*1)
No fracturing of elements allowed
±
 15 kV
Indirect discharge
Element allowable level 
(self-printing)
±
 15 kV
Checker connection allowable level 
(continuous printing)
±
 3 kV (*2)
Direct discharge error: 
5%
(*1) 
±
10 kV test is also performed.
Indirect discharge error: 0%
(*2) 
±
5 kV test is also performed.
Item
Specification
Frequency
7 ~ 100 ~ 7 Hz (sweeping: 2.5 minutes)
Amplitude
15.3 ~ 0.07 mm
Gravity
1.5 G (constant)
Vibration direction and
time
1 hour in each direction: X, Y and Z
Total of 3 hours
Packing
As small as possible
Item
Specification
Drop height
80 cm
Drop sequence
One corner, three edges and six surfaces
Packing
As small as possible