Varec TankGate Interface 8315 Series Benutzerhandbuch
8315 L&J Tankway Software Description
TankGate Interface
34
Installation and Operations Manual
4.6
Clock (CLK)
The Clock point provides access to the System Clock. Standard time format
is in the form of MM/DD/YY HH:MM:SS.
4.6.1
Parameters
The database parameters used by the CLK point are listed and described below:
Configuration Parameters
Function
TZ
Time Zone string
Dynamic Parameters
Function
SysTime
System Time in the form MM/DD/YY HH:MM:SS. Writing to
this value will change the system time.
SysTicks
Time if “ticks” format. Ticks are incremented every 10
msec, with the initial value of 0 equal to Jan. 1, 1970 at
00:00:00
timezone
Time zone relative to GMT. The timezone is entered in
seconds.
Example: Eastern Time Zone = 18000; Pacific = 28800
daylight
Daylight Savings Flag