Vogelzang International Defender High Efficiency Air-Tight Woodstove TR001 Benutzerhandbuch

Seite von 19
Page 18 
TR001 DEFENDER™
VGZ-026 / 052705.0
A. Brick Masonry
Minimum 3.5-inch thick brick masonry all framed into
combustible wall with a minimum of 2-inch brick sepa-
ration from clay liner to combustibles. The fireclay liner
shall run from outer surface of brick wall to, but not
beyond, the inner surface of chimney flue liner and shall
be firmly cemented in place.
B. Insulated Sleeve
Solid-insulated, listed factory-built chimney length of
the same inside diameter as the chimney connector and
having 1-inch or more of insulation with a minimum
9-inch air space between the outer wall of the chimney
length and combustibles.
C. Ventilated Thimble
Sheet steel chimney connector, minimum 24 gauge in
thickness, with a ventilated thimble, minimum 24 gauge
in thickness, having two 1-inch air channels, separated
from combustibles by a minimum of 6-inch of glass
fiber insulation. Opening shall be covered, and thimble
supported with a sheet steel support, minimum 24 gauge
in thickness.
D. Chimney Section Pass-through
Solid insulated, listed factory-built chimney length with
an inside diameter 2-inch larger than the chimney con-
nector and having 1-inch or more of insulation, serving
as a pass-through for a single wall sheet steel chimney
connector of minimum 24 gauge thickness, with a mini-
mum 2-inch air space between the outer wall of chim-
ney section and combustibles. Minimum length of chim-
ney section shall be 12-inch chimney section spaced
1-inch away from connector using sheet steel support
plates on both ends of chimney section. Opening shall
be covered, and chimney section supported on both sides
with sheet steel support securely fastened to wall
surfaces of minimum 24 gauge thickness. Fasteners used
to secure chimney section shall not penetrate
chimney flue liner.
CHIMNEY CONNECTOR SYSTEMS & CLEARANCES