Siemens TV Converter Box 611 Benutzerhandbuch
![Siemens](https://files.manualsbrain.com/attachments/fea10bc852adcb1f4f76708d5daebca542e532b9/common/fit/150/50/c53f5738b57089fc3d6c279e23db7450685a19c9616727fc1f659077967b/brand_logo.png)
Technical data and characteristics
14.2 Data sheets and diagrams
Data sheet 1FW6090-xxB10-xxxx
Table 14- 3 1FW6090-xxB10-0Kxx, 1FW6090-xxB10-1Jxx
Technical data
1FW6090
1FW6090
Symbol
Unit
-xxB10-0Kxx -xxB10-1Jxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
Rated temperature of winding
T
N
°C
130
130
Rated data
Rated torque
M
N
Nm
231
216
Rated current
I
N
A
7.9
14
Maximum speed at rated torque
n
MAX,MN
rpm
82
270
Rated power dissipation
P
V,N
kW
3.5
3.5
Limit data
Maximum torque
M
MAX
Nm
358
358
Maximum current
I
MAX
A
13
26
Electric power of motor at M
MAX
P
EL,MAX
kW
9.43
15.3
Maximum speed at maximum torque
n
MAX,MMAX
rpm
8.7
170
No-load speed
n
MAX,0
rpm
220
430
Torque at n = 1 [rpm]
M
0
Nm
238
238
Current at M
0
and n = 1 [rpm]
I
0
A
8.2
16
Thermal static torque
M
0
*
Nm
168
168
Thermal stall current
I
0
*
A
5.6
11
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
30
15
Voltage constant
k
E
V/(1000/min)
1812
906.2
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
4.17
4.17
Thermal time constant
t
TH
s
60
60
No. of pole pairs
p
-
22
22
Cogging torque
M
COG
Nm
2.4
2.4
Stator mass
m
S
kg
12.1
12.1
Rotor mass
m
L
kg
5.1
5.1
Rotor moment of inertia
J
L
10
-2
kgm
2
3.09
3.09
Phase resistance of winding at 20 °C
R
STR, 20
Ω
12.4
3.09
Phase inductance of winding
L
STR
mH
47.5
11.9
Data, main motor cooler
Maximum dissipated thermal power
Q
H,MAX
kW
2.91
2.91
Recommended minimum volume flow rate
H,MIN
l/min
5.4
5.4
Temperature increase of the coolant
ΔT
H
K
7.7
7.7
Pressure drop
Δp
H
bar
0.4
0.4