Siemens TV Converter Box 611 Benutzerhandbuch
Technical data and characteristics
14.2 Data sheets and diagrams
14.2.7
1FW6290-xxxxx-xxxx
Data sheet 1FW6290-xxB07-xxxx
Table 14- 40 1FW6290-xxB07-5Gxx, 1FW6290-xxB07-0Lxx, 1FW6290-xxB07-2Pxx
Technical data
1FW6290
1FW6290
Symbol
Unit
-xxB07-5Gxx -xxB07-0Lxx -xxB07-2Pxx
Boundary conditions
DC link voltages
U
ZK
V
600
600
600
Water cooling inlet temperature
T
VORL
°C
35
35
35
Rated temperature of winding
T
N
°C
130
130
130
Rated data
Rated torque
M
N
Nm
2060
1910
1810
Rated current
I
N
A
52
86
100
Maximum speed at rated torque
n
MAX,MN
rpm
110
210
270
Rated power dissipation
P
V,N
kW
5.19
5.19
5.2
Limit data
Maximum torque
M
MAX
Nm
4000
4000
4000
Maximum current
I
MAX
A
110
210
270
Electric power of motor at M
MAX
P
EL,MAX
kW
47.7
70.6
85.4
Maximum speed at maximum torque
n
MAX,MMAX
rpm
59
110
150
No-load speed
n
MAX,0
rpm
160
280
360
Torque at n = 1 [rpm]
M
0
Nm
2220
2220
2220
Current at M
0
and n = 1 [rpm]
I
0
A
56
100
120
Thermal static torque
M
0
*
Nm
1570
1570
1570
Thermal stall current
I
0
*
A
39
70
90
Physical constants
Torque constant at 20 °C
k
T,20
Nm/A
39.8
22.4
17.4
Voltage constant
k
E
V/(1000/min)
2405
1352
1053
Motor constant at 20 °C
k
M,20
Nm/(W)
0.5
31.2
31.2
31.2
Thermal time constant
t
TH
s
180
180
180
No. of pole pairs
p
-
42
42
42
Cogging torque
M
COG
Nm
11
11
11
Stator mass
m
S
kg
72.6
72.6
77.8
Rotor mass
m
L
kg
31
31
31
Rotor moment of inertia
J
L
10
-2
kgm
2
228
228
228
Phase resistance of winding at 20 °C
R
STR, 20
Ω
0.389
0.123
0.0747
Phase inductance of winding
L
STR
mH
6.4
2
1.2
Data for main motor cooler *)
Maximum dissipated thermal power
Q
H,MAX
kW
3.9
3.9
3.91
Recommended minimum volume flow
H,MIN
l/min
5.8
5.8
5.8
1FW6 Built-in torque motors
290