Pelco Coaxitron Receiver/Driver CX9000 Benutzerhandbuch

Seite von 28
Pelco Manual C554M-A (5/98)
21
Figure 7.  AC Input and Fuse Values
F3
F2
F1
POWER            OUTPUT
INPUT               P/T
VAC                  VAC
   
CX9024RX
CX9024RXI
 *12VDC Camera
   options use a
   1/2ASB fuse
   value in this
   position in place
   of the 2/10's
   value.
    
*CX9024RXI-12V
*CX9024RX-12V
CX9024RX-PP
CX9024RXI-PP
CX9224RX
CX9224RX-PP
CX9224RXI
CX9224RXI-PP
*CX9224RXI-12V
CX9115RX
CX9115RX-PP
CX9115RXI
CX9115RXI-PP
1ASB
2/10ASB
*1/2ASB
NOT
USED
.5A/250V
5X20MM
.1A/250V
5X20MM
2/10ASB
1/10ASB
1/2ASB
1A
1ASB
2/10ASB
2/10ASB
120VAC
24VAC
P/T OUT
IN
P/T
CAMERA
PC BOARD
230VAC
IN
  24VAC
 P/T OUT
230VAC
IN
230VAC
P/T OUT
24VAC
IN
24VAC
P/TOUT
120VAC
IN
120VAC
P/T OUT
A P P L I C A B L E     M O D E L S
Additional
combinations
of equip-
ment options
are possible
depending
on custom-
er  need &
availability.
This listing
covers the 
most used
and/or the 
most available
type units &
their options.
NOT
USED
NOT
USED
3A
CX9024RX/220
CX90224RX-PP220
CX9220RX
CX9220RX-PP
CX9220RXI
CX9220RXI-PP
3AG TYPE 
FUSE
3AG TYPE FUSE
3AG TYPE FUSE
3AG TYPE 
FUSE
*The CX9224
option with 
12 VDC camera 
uses one fuse 
in the F3 
position. It is a 
3A fuse not a 
3ASB fuse. 
Fuse positions 
F1 and F2 are 
not used.
 
**
**
AC INPUT DESIGNATIONS
1.  AC HIGH
2.  GROUND
3.  AC LOW
F1
F2       FUSE
F3
SW 1    SHOWN IN THE “LONG” POSITION
**
SW1    SHOWN IN THE “SHORT” POSITION
P2
P1
PC BOARD
TRANSMITTER: F1 2/10 ASB, 3AG
RECEIVER FUSE VALUES: SHOWN BELOW
BNC CONNECTORS
37-PIN AMP CONNECTOR
POWER INPUT
FOR REV K BOARDS, THE SW1 SWITCH 
POSITIONS SHOWN ABOVE ARE JUST
REVERSED, THAT IS, “SHORT” IS “LONG”