Toro Aqua-Clear Fiberglass Sand Filters Broschüre

Seite von 2
Sizing Recommendations
Flow (gpm)
50
75
100
125 150 175 200 225 250 275 300 325 350 375 400
Filter Quantity x
Tank Size
2 x 18"
2 x 24"
3 x 24"
3 x 30"
3 x 36"
This table shows the filter recommendations for moderately dirty water. Always size the filter station for water flow at the maximum crop
demand and the time of year when the water source is the most dirty. 
If your water source is heavily contaminated at some point in the irrigation season, consider selecting the next size filter system.
Aqua-Clear
Fiberglass Sand Filters
D A
B
C
Vertical Clearance Required
7-
1
2
"
©2014 The Toro Company
Micro-Irrigation Business
1588 N. Marshall Avenue, El Cajon, CA 92020-1523, USA
Tel: +1 (800) 333-8125 or +1 (619) 562-2950
Fax: +1 (800) 892-1822 or +1 (619) 258-9973
toro.com
ALT199 07/14
Filter Dimensions
Part
Number
A DIM.
B DIM.
C DIM.
D DIM.
AC-40
30-
1
2
"
19-
1
2
"
10-
3
4
"
40
AC-60
35-
1
2
"
24-
1
2
"
13-
5
8
"
45
AC-100
39-
3
4
"
30-
1
2
"
16-
1
4
"
50
AC-140
45-
1
4
"
36-
1
2
"
18-
3
4
"
55
Automated Filter Systems
Solenoid
Type
Part Number
18" Tank
24" Tank
30" Tank
36" Tank
2x Filter System
DCL
AC
ACS-218-12VDCL
ACS-218-24VAC 
ACS-224-12VDCL
ACS-224-24VAC 
ACS-230-12VDCL
ACS-230-24VAC 
ACS-236-12VDCL
ACS-236-24VAC 
1x Filter Expansion*
DCL
AC
ACX-118-12VDCL
ACX-118-24VAC 
ACX-124-12VDCL
ACX-124-24VAC 
ACX-130-12VDCL
ACX-130-24VAC 
ACX-136-12VDCL
ACX-136-24VAC 
Part numbers above include filter, valves, air vents and controller.
PVC pipe and fittings for the manifolds to be sourced locally; details in Operations Manual.
*The 1x Expansion adds one filter to an existing complete filter system of 2 or more filters. For example: For a 3-filter system with 30" tanks and
an AC solenoid, order one unit of ACS-230-24VAC and one unit of ACX-130-24VAC.
Filter Specifications
Part
Number
Tank Size
Filtration
Area
(sq. ft.)
Maximum Flow Rate (gpm)
Minimum
Backflush 
(gpm)
Gravel 
(lbs.)*
Sand
Required
(lbs)
1 Filter
2 Filter
3 Filter
AC-40
18"
1.92
38
75
110
29
50
125
AC-60
24"
3.14
62
120
175
47
50
275
AC-100
30"
4.91
74
150
275
74
150
450
AC-140
36"
7.06
106
160
400
106
275
650
* Gravel is not required for these filters, although some operators prefer to use it. If gravel is not used, add this quantity of sand instead.