Crown Audio TP-170V Merkblatt

Seite von 2
TP-170V
T
he Crown
®
 TP-170V is a rack-mountable 
panel with autoformers to provide imped-
ance matching between amplifi er outputs 
and “constant voltage” loudspeakers. This unit 
allows amplifi ers without direct 70V or 100V 
output capability to drive distributed speaker 
systems designed to operate at those voltages.
The TP-170V is constructed of sturdy steel, and 
hinged on one side to allow easy access to the 
inside connections.
For more details about the Crown TP-170V, 
contact Crown Customer Service at 
800-342-6939 or 574-294-8200. Also, visit the 
Crown Audio website at www.crownaudio.com.
Specifi cations
Output connectors: One fi ve-pole terminal strip 
per channel with touch-proof cover. Accepts up 
to 10 AWG terminal forks.
Frequency Response: +/- 0.5 dB (20 Hz to 20 
kHz).
Insertion (Core) Loss: 0.41 dB max (70VAC at 
50 Hz).
Dimensions: 
19 in (48.3 cm) wide (including hinge)
7.23 in (18.4 cm) high
1.45 in (3.7 cm) deep.
Weight: 12.75 lbs (5.78 kg).
Installing the TP-170V
CAUTION: Before you begin, make sure your 
amplifi er is disconnected from the power 
source, with the power switch in the “off” 
position and all level controls turned com-
pletely down (counterclockwise)
.
Use a standard 19-inch (48.3-cm) equipment 
rack (EIA RS-310B) to install the TP-170V.
Connect the Grounding Strap
Connect the TP-170V grounding strap to a rack 
rail or rack ground, and be sure the rack is 
grounded to an AC mains safety ground. (Test 
the AC mains ground to make sure it is reli-
able). If you are not using a rack, be sure to 
connect the TP-170V grounding strap to an AC 
mains safety ground and mount the unit in a 
metal box for safety. Insulate the TP-170V from 
the box. 
CAUTION: Do not remove the grounding strap 
or leave it unconnected.
Choose Output Wire and Connectors
Crown recommends using professionally con-
structed, high quality, two- or four-conductor, 
heavy gauge speaker wire and connectors. You 
may use terminal forks or bare wire for your 
output connectors. The TP-170V terminal strips 
accept up to 10 AWG terminal forks which fi t 
over a #8 screw.
CAUTION: Use insulated terminal forks to pre-
vent shorting against the touch-proof cover 
plate.
To connect TP-170V outputs, fi rst remove the 
touch-proof cover plate covering the output 
terminal strip by removing the three screws 
which hold it in place. To prevent the possibility 
of short-circuits, wrap or otherwise insulate 
exposed loudspeaker cable and connectors. 
Reinstall the cover plate.
Wire Your System
Refer to the chart in Figure 1 to determine the 
proper transformer tap to use, based on the 
rated output power of your amplifi er and the 
desired constant-voltage of your system. Then 
wire the connections as shown in the corre-
sponding wiring diagram in Figs. 2 through 4.
CAUTION: Never use shielded cable for output 
wiring.
CONSTANT-VOLTAGE TRANSFORMER PANEL
   
  Features
  •  Four autoformers per panel provide four channels of impedance matching for Constant-Voltage    opera-
tion
  •  Provides 100V output in Dual mode when used with CTs 600, CTs 1200, CTs 4200 and CTs 8200 ampli-
fi ers
  •  Allows amplifi ers without direct Constant-Voltage capability to be easily integrated into distributed 
systems
  •  Convenient hinged rack mounting allows easy access to connections