Jettech Metal Products FX-44 Benutzerhandbuch

Seite von 36
 
 
 
 
 
 
 
 
 
 
 
The on time can be modified by acting on the following buttons: 
The measuring device operation is disabled when the value 0 is set. 
 
 
The set time will be automatically saved. To exit this mode just keep the A button pressed until the machine-off dashes 
are displayed. 
We recommend you set the most appropriate value according to the manufacturer’s recommended dose. 
Perform a few test washes to complete the adjustment stage. 
 
 
 
 
 
4.9   Detergent measuring device (optional) adjustment: 
 
 
 
The quantity of detergent can be adjusted by determining the measuring device on/off time. 
Follow these instructions: 
 
 
 
 
 
 
 
 
 
 
Turn off the machine, open the door and keep the C and D buttons pressed for 5 seconds. 
 
The following will then appear: 
 
 
 
 
 
Display the following by using the C button: 
 
 
 
 
 
 
 
 
 
 
 
 
Confirm the entry to the main menu mode using the D button 
 
 
 
 
 
 
 
 
Then scroll the various menu items using the A button 
until the following appears: