DSCover Satellite Products Home Security System PC1555MX Benutzerhandbuch
P r o g r a m m i n g W o r k s h e e t s
29
Keypad Programming
[000] Keypad
Enrollment
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; i.e. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-21)
[2] Function Key 2 Assignment (Valid entries are 00-21)
[3] Function Key 3 Assignment (Valid entries are 00-21)
[4] Function Key 4 Assignment (Valid entries are 00-21)
[5] Function Key 5 Assignment (Valid entries are 00-21)
Function Key Options:
[1] Function Key 1 Assignment (Valid entries are 00-21)
[2] Function Key 2 Assignment (Valid entries are 00-21)
[3] Function Key 3 Assignment (Valid entries are 00-21)
[4] Function Key 4 Assignment (Valid entries are 00-21)
[5] Function Key 5 Assignment (Valid entries are 00-21)
Function Key Options:
Slot
Function
Function
Function
Function
Function
Key 1
Key 2
Key 3
Key 4
Key 5
LED Defaults
11
03
04
06
14
16
LCD Defaults
18
03
04
06
14
16
KEYPAD 1
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 2
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 3
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 4
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 5
I________I________I I________I
I________I
I________I
I________I
I________I
KEYPAD 6
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 7
I________I________I I________I
I________I
I________I
I________I
I________I
KEYPAD 8
I________I________I
I________I
I________I
I________I
I________I
I________I
Basic Programming
Zone Definitions
NOTE: Keypads must be installed to use 24-hour Buzzer zones.
NOTE: Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in
sections [202] - [205].
sections [202] - [205].
[001] Zone 1-8 Definitions
Default
Default
01
I_______I_______I
Zone 1
04
I_______I_______I
Zone 5
03
I_______I_______I
Zone 2
04
I_______I_______I
Zone 6
03
I_______I_______I
Zone 3
00
I_______I_______I
Zone 7
03
I_______I_______I
Zone 4
00
I_______I_______I
Zone 8
00 Null Key
08 [*][1] Bypass Mode
16 [*][0] Quick Exit
01 For future use
09 [*][2] Trouble Display
17 [*][1] Reactivate Stay/Away’s
02 For future use
10 [*][3] Alarm Memory
18 Identified Voice Prompted Help
03 Stay Arm
11 [*][5] User Programming
19 Command Output 3
04 Away Arm
12 [*][6] User Functions
20 For Future Use
05 [*][9] No-Entry Arm
13 Command Output #1 [*][7][1]
21 Command Output 4
06 [*][4] Chime On / Off
14 Command Output #2 [*][7][2]
07 [*][6][——][4] System Test
15 General Voice Prompted Help
00 Null Zone (Not Used)
10 24 Hour Supervisory Buzzer
20 24 Hour Freeze
01 Delay 1
11 24 Hour Burglary
21 24 Hour Latching Tamper
02 Delay 2
12 24 Hour Holdup
22 Momentary Keyswitch Arm
03 Instant
13 24 Hour Gas
23 Maintained Keyswitch Arm
04 Interior
14 24 Hour Heating (N/C zone)
24 LINKS Answer
05 Interior, Stay/Away
15 24 Hour Medical
25 Interior Delay
06 Delay, Stay/Away
16 24 Hour Panic
87 Delay 24 Hour Fire (Wireless)
07 Delayed 24 Hour Fire (Hardwired)
17 24 Hour Emergency
88 Standard 24 Hour Fire (Wireless)
08 Standard 24 Hour Fire (Hardwired)
18 24 Hour Sprinkler
09 24 Hour Supervisory
19 24 Hour Water
WWW.DIYALARMFORUM.COM