Shared IRQ Mode 
 
The 3PXCC4A card has the ability to share interrupts 
among its ports. Shared IRQ mode should only be used if your 
software supports this feature. If you are writing your own software, 
B&B Electronics’ SimpCom V1.04 and later serial communications 
library supports this feature. 
 
When sharing ports, use JP5 to set each of the ports to be 
used in shared mode to the SHARE position. JP6 must also be set 
to the SHARE position. Each of the ports set to SHARE will use the 
Port A IRQ. Therefore when sharing IRQs among two or more ports, 
Port A must always be one of the shared ports.