B&B Electronics Switch 232XS5 Benutzerhandbuch

Seite von 26
  
232XS53800 
Manual 
B&B Electronics  --  PO Box 1040  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815) 433-5109
 
12
 
If the data byte of the Set Timer Mode command is an ASCII “1”, 
the timer will be setup to ignore switching commands.  Sending the 
following string to the 232XS5 will set up the timer to ignore 
switching commands.  (Assuming programmable character is the 
factory default of 2). 
 
SetTM$ = CHR$(27) + CHR$(2) +”M” + “1” 
 
The “M” tells the 232XS5 it is the set timer mode command and the 
“1” indicates to set up the timer to ignore switching commands.  
When the timer is configured in this mode, the 232XS5 will not 
accept any switching commands (“A”, ”B”, ”C”, ”D”, “E”, or “EOT”) for 
the specified timer value.  After the timer has expired, the slave port 
that is connected to the master port will be disconnected.  This 
feature is useful to prevent inadvertent switching during 
binary/graphic type file transfers.  For example (smart switch mode), 
the timer is configured to ignore switching commands for 5 seconds.  
The select Port D command is sent to the 232XS5.  Once Port D is 
connected a file of unknown data type (so file may or may not 
contain a switching command sequence) is to be transferred 
through the 232XS5.  For a period of 5 seconds after Port D is 
connected, no switching commands will be accepted.  As long as 
the file transfer takes less than 5 seconds, there is no chance the 
232XS5 will inadvertently switch ports. 
 
Table 8 - 232XS5 Smart Switch Mode Commands 
*X represents the programmable character set by dipswitch SW2 
**NU = Not Used 
 Command 
Characters  
Function 1st 
2nd 
3rd 
4th 
Comments 
Select Port A 
ESC 
X* 
“A” 
NU**  Switching Command 
Select Port B 
ESC 
X* 
“B” 
NU**  Switching Command 
Select Port C 
ESC 
X* 
“C” 
NU**  Switching Command 
Select Port D 
ESC 
X* 
“D” 
NU**  Switching Command 
Select Port E 
ESC 
X* 
“E” 
NU**  Switching Command 
Deselect Port 
ESC 
X* 
EOT
NU**  Switching Command 
Set Timer Value 
ESC 
X* 
“T” 
“0”-”9” 
Enhanced Mode 
Set Timer Mode 
ESC 
X* 
“M” 
“0”,”1” 
Enhanced Mode