Connecting to the Alarm Port
2
Connecting to the Alarm Port
The DB-15 alarm port on the switch’s front panel is used to provide alarm. The switch supports two 
sets of alarm relay contacts (major and minor), and 4 external customer site alarm inputs. The pin 
assignments used to connect to the alarm port are provided in the following table.
FIGURE 19
ALARM PORT (D-15) PIN OUT
Wiring Map for Alarm Cable
The signals include relay contacts for major and minor system alarms, and external alarm inputs.
* P indicates positive input.
† RTN indicates return to Ground.
TABLE 4
SYSTEM STATUS LEDs
Switch’s Alarm Port
Funtion
1 (MJR_ALARM_CNTR)
Common contact for major alarm relay.
2 (MNR_ALARM_CNTR)
Common contact for minor alarm relay.
3 (ALARM_IN3_EXT_P*)
External alarm input 3 (external relay dry contact closure to pin 13).
4 (ALARM_IN4_EXT_P)
External alarm input 4 (external relay dry contact closure to pin 8).
5 (No Contact)
6 (MJR_ALARM_NO)
Normally open during major alarm state.
7 (MNR_ALARM_NO)
Normally open during minor alarm state.
8 (ALARM_IN4_EXT_RTN†)
External alarm input 4 (external relay dry contact closure from pin 3).
9 (ALARM_IN1_EXT_P)
External alarm input 1 (external relay dry contact closure to pin14).
10 (ALARM_IN2_EXT_P)
External alarm input 2 (external relay dry contact closure to pin 15).
11 (MJR_ALARM_NC)
Normally closed during major alarm state.
12 (MNR_ALARM_NC)
Normally closed during minor alarm state.
13 (ALARM_IN3_EXT_RTN)
External alarm input 3 (external relay dry contact closure from pin 3).
14 (ALARM_IN1_EXT_RTN)
External alarm input 1 (external relay dry contact closure from pin 9).
15 (ALARM_IN2_EXT_RTN)
External alarm input 2 (external relay dry contact closure from pin 10).