Brother MD-611 Benutzeranleitung

Seite von 84
6. USING THE OPERATION PANEL (ADVANCED OPERATIONS) 
 
BAS-300G, BAS-311G, BAS-326G 
34
6-2. Setting memory switches 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Menu indicator switches off
TEST indicator illuminates
While pressing the SELECT key, turn on the power 
switch.
 
*  Keep pressing the SELECT key until the model name 
is displayed and the buzzer beeps once. 
 
 
 
 
 
 
or 
With the power turned on, press the TEST key and the 
TENSION/WIND key simultaneously.
 
 
 
 
 
• The memory switch number will appear in the 
PROGRAM No. display, and its setting value will 
appear in the menu display. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Press the 
 or   
key to select the memory switch 
number.
 
 
 
 
Press the 
 or   
key to change the setting.
 
 
If you would like to display only the numbers of 
memory switches that have been changed from 
default settings 
 
 
 
 
 
 
 
 
 
While pressing the SELECT key, press the 
 or   
key.
• The numbers of memory switches that have been 
changed from default settings will appear in order. 
•  If no memory switches have been changed from their 
default settings, the display will not change and the 
buzzer will beep twice. 
Ending setting mode 
 
 
 
TEST indicator switches off
Press the TEST key.
 
• The changes will be memorized and the sewing 
machine will switch to home position detection standby.
 
 
• 
If you would like to return the setting for a single memory switch to the default setting, press the 
RESET key while the number for that memory switch is displayed.
 
 
• 
To return the settings for all memory switches to the default settings, keep pressing the RESET key 
for two or more seconds until the buzzer makes a long beep.
 
4421Q
4449Q
4961Q
4452Q
All indicators switch off