Wayne-Dalton Wireless Wall Station Produkthandbuch

Seite von 2
Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need
You can reach us Toll Free at 1-888-827-3667 for Consum er Assistance or online at w w w .w ayne-dalton.com
28
I
Up-Dow n Button:
Momentarily pressing the Up/Down button starts or stops door 
movement or changes door’s direction. Pressing and holding Up/
Down button during the door’s travel will override safety sensors. The 
Up/Down Button (when unit is closed) can be activated by pressing 
flip cover.
IF DOOR REQUIRES THAT SAFETY SENSORS BE OVERRIDDEN 
THAT CONDITION MUST BE CORRECTED IMMEDIATELY. FAILURE 
TO MAKE ADJUSTMENTS/REPAIRS COULD RESULT IN SEVERE 
OR FATAL INJURY.
Light Button:
Momentarily pressing the light button turns on the convenience light. 
The light will remain on until either the light button is pressed again 
or the door is activated. The light automatically turns on with a door 
activation and remains on for 4 minutes. Pressing the light button 
before the 4 minutes has elapsed will turn off the light. W hile the 
door is in motion, the light button functions identically as the Up/
Down button, stopping or reversing the door immediately.
Tim er Button:
Momentarily pressing the timer button causes a delayed activation of 
a stationary fully open door. The light fixture or the opener’s lamp will 
blink on and off for about 10 seconds prior to closing the door, 
allowing enough time to exit the garage when the opener is in the 
timer mode. Pressing any button, except the program button while 
the opener lamp is blinking cancels the timer mode. 
NOTE: The timer feature will only function with the door in the full 
open position. Pressing the timer button with a stationary door in any 
other position will cause the opener lamp to blink 4 times and the 
door will not be activated.
W hile the door is in motion, the timer button functions identical to 
the Up/Down button, stopping or reversing the door immediately.
Vacation Slide Sw itch:
The slide switch has two positions: Normal, and Door lock.
Normal position: 
Move the slide switch to normal position for all normal functions of 
the opener. The normal position will cancel the door lock feature.
NOTE:  W hen the slide switch is moved to the unlocked position the 
opener light fixture will blink on/off three times.
Door Lock position: 
If the door is stopped (fully open, fully closed or partially open) move 
the slide switch to the door lock position to suspend all normal 
functions of the opener. The opener will remain completely disabled 
and non-operational in this mode. All wall stations, transmitters and 
keyless entry units are ignored until the slide switch is moved to the 
normal position. If the door is moving when the slide switch is 
moved to the door lock position, the door lock mode is not activated 
and all functions of the opener remain active.
NOTE: W hen the slide switch is moved to the locked position the 
opener light fixture will blink on/off three times.
Operating the W ireless W all Station
Backlit LED Light:
The red LED blinks intermittently to help you locate the wall station in a 
dark garage. This blink rate can be changed for longer battery life or can 
be turned off. The default blink rate is one blink every 3 seconds. For 
longer battery life the blink rate can be changed to blink once every 6 
seconds. To change the blink rate, remove the battery cover and remove 
one battery. Re-install the battery and within 2 seconds, press the Light 
button. Re-install the battery cover.
For longest battery life, the blink can be turned off. To turn off the blink, 
remove the battery cover and remove one battery.
Re-install the battery and within 2 seconds, press the Pet button. Re-
install the battery cover.
NOTE: The wall station’s red LED will blink rapidly while any wall station 
button remains pressed.
Pet Position:
Pressing the pet button opens a closed door to a preset position between 
5 and 30 inches above the floor, allowing pets to enter and exit the 
garage without the door being fully open. The door must be fully closed 
to activate the pet open feature. Pressing the pet button with a stationary 
door in the pet open position will cause the door to close. Pressing the 
Up/Down button while the door is in the pet position will cause the door 
to open. W hile the door is in motion, the pet button functions identically 
to the Up/Down button, stopping or reversing the door immediately. The 
pet feature allows for custom setting of the pet position door height. 
NOTE: A door in the “pet position” (open 5-30 inches) is not locked and 
should not be used as a secured door position.
Program  Button:
The wall station program button has several functions.                         
a. It can be used to set a custom pet position. (see Customizing the 
Settings, on the next page)                                                 
b. It can be used to set the opener’s closing force (see Adjustment  
 
  #1 Page 32).            
                                                            
Pet Button
Light Button
Up/Down Button
Timer Button
    W ARNING
Program Button
Vacation                        
Slide Switch