Features and Benefits
-  i SEER
TM
Energy efficient brushless DC (ECM) motor gives up 
to 1 SEER point efficiency gain in cooling.
-  Modulating heating operation Includes: 
  -  Modulating gas valve from 100% to 50% input  
  in 5% increments
  -  Time proportioning modulation down to 15%
  -  Variable speed inducer and blower.
-  100% fired and tested: All units and each component  are 
tested on the manufacturing line.
-  Best packaging in the industry: Unique corner post design 
assures product will arrive to the homeowner dent free.
-  30 second blower delay: At start-up assures a warm duct 
temperature at furnace start-up. Adjustable blower off settings 
(60, 90, 120 and 180 seconds).
-  30 second post purge: Increases life of heat exchanger.
-  Hot surface igniter: Innovative application of an appliance 
type igniter with a 20 year history of reliability. Utilizes proven 
SmartStart® technology.
-  Color coded wire harness: Designed to fit the components, all 
with quick-connect fittings for ease of service and replacement.
-  Flexible category IV venting system: May be vertically or 
horizontally vented using either a one-pipe or two-pipe system 
for maximum flexibility in installation.
-  High Static Blowers: All models equipped with high static 
blowers.
-  Low Boy Height: Easy to apply in low ceiling applications, 
works well with taller high SEER coils, easier to handle and 
install.
-  Tubular primary heat exchanger: Heavy gauge aluminized  
steel heat exchanger and stainless steel secondary heat 
exchanger assures a long life.
-  90 second fixed cooling cycle blower-off  delay (TDR): Increases 
cooling performance when matched with a NORDYNE coil.
-  LP convertible: Simple burner orifice and regulator spring 
change for ease of convertibility.
-  Diagnostic lights for easy troubleshooting without counting 
flashes:  Dedicated light for flame signal strength and 2 lights 
in combination to indicate all other fault codes with easy to 
recognize states without counting flashes.
-  Incorporates integrated control board: With connections for 
electronic air cleaner, and humidifier.
-  Two piece door design: Enhances furnace appearance and 
uses captured screws to prevent losing door screws.
-  Blower Compartment: Sealed door to reduce air leakage and 
insulated for ultra quiet operation.
-  Sealed Vestibule: Reduces burner and inducer sound levels.
-  iQ Drive Thermostat: Provides modulation down to 15% and 
is required for furnace operation.
The high efficiency gas furnace 
may be installed free standing 
in a utility room, basement, or 
enclosed in an alcove or closet. 
The rounded corner jacket 
provides a pleasing “appliance 
appearance.” Design certified by 
CSA for application in Canada 
and the United States.