Leibherr USA Refrigerators and freezers for integrated use, door-on-door HRB 1110 HF 851 Benutzerhandbuch

Seite von 14
Note
u
In case of disassembly: Press back the dark grey ring on
the plug-in elbow and pull out the hose at the same time.
u
Pull the tray
 Fig. 33 (4)
out until it catches.
u
Secure  the  module
with 
screws
Fig. 33 (5)
 through the
recesses  in  the  front
and  directly  through
the  module  in  the
back.
Fig. 33 
u
Place  the  tray  cover
Fig. 35 (3)
 in position.
Fig. 34 
Fig. 35 
u
Insert the water filter
 Fig. 35 (6)
 and turn it approximately
100° to the right until it locks into position.
u
Place the cover
 Fig. 35 (2)
 on the filter.
u
Slide the tray in.
u
Write  the  date  of  the  next  filter  replacement  on  the
supplied adhesive label and affix it to the module.
u
Make sure the filter is leak-tight and no water is coming
out.
Note
New water filters may contain particulate matter and must
be rinsed through before use.
u
To achieve this, do not consume or use the ice cubes that
are produced within 72 hours after the filter is replaced.
w
The water filter is now ready for use.
8 Connecting the appliance
WARNING
Electrical shock hazard!
u
Start-up should only take place once the appliance has
been installed according to these instructions.
u
Electrically ground appliance.
u
Do not ground to a gas pipe.
u
Check with a qualified electrician if you are not sure the
appliance is properly grounded.
u
Do not have a fuse in the neutral or grounding circuit.
u
Do not use an extension cord, power bar or a multiple
socket adapter.
u
Do not use a power cord that is frayed or damaged.
WARNING
Electrical shock hazard!
This appliance is equipped with a three-prong (grounding)
polarized plug for your protection against possible shock
hazards. Electrical Grounding Required.
u
Do not remove the round grounding prong from the plug.
u
Do not use a two-prong grounding adapter.
- Wait 30 minutes up to 1 hour after installation before you
plug  in  the  appliance.  This  allows  the  refrigerant  and
system lubrication to reach equilibrium.
- Make sure incoming voltage is the same as the appliance
rating. A 110-120 Volt, 60 Hz, 15 Amp electrical supply
(20  Amp  for  side-by-side  installations)  circuit  that  is
controlled by a circuit breaker or fuse is required.
- We  recommend  using  a  dedicated  circuit  for  this
appliance to prevent electrical overload.
- Follow  all  Federal,  State  and  local  electrical,  fire  and
building  codes  and  ordinances  when  installing  the
receptacle and / or the appliance.
- In some communities, a wall switch is required to turn
power to the appliance ON and OFF.
- To  reduce  the  risk  of  fire,  electric  shock,  or  personal
injury,  installation  work  and  electrical  wiring  must  be
done  by  a  qualified  electrician  in  accordance  with  all
applicable  codes  and  standards,  including  fire-rated
construction.
- You are advised to clean the appliance before switching
it on the first time .
- The  top  of  the  electric  outlet  must  be  located  within
82-5/8  in.  (2100  mm)  from  the  top  of  the  base  in  the
cabinet.
Connecting the appliance
14