COMBINATION INSTALLATIONS
DR30DI Range with ERV3015 
 Raised Vent
Document # PGCI-026
Revised 01/13/12   Page 1/2
 warning
•  Observe all governing codes and ordinances during planning 
and installation. Contact your local building department for 
further information.
•  All appliances must be installed in accordance with the 
accompanying installation instructions.
Model Dr30Di 
range and ErV3015
raised Vent with
a
B
C
Countertop self-
rimmed only
20 5/8”
(52.4 cm)
0” (0 cm) to
3 1/4” (8.3 cm)
0” (0 cm) to
5 3/8” (13.7 cm)
Countertop height for all self-rimming installations:  
35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum
Self-rimming installation with raised Vent  
(Option 1)
 
Only model DR30DI may be installed with a raised vent. Use only 
Dacor raised vent model ERV3015.
 
A self-rimming countertop configuration is required for raised vent 
installation. On installations with a raised vent, when sliding the range 
into position, it will stop when the rear of the control panel or side 
panels contact the notches toward the front of the countertop.
 
The self-rimming installation of the DR30DI range and ERV3015 
raised vent create a “built-in” look where the range trim overlaps the 
countertop on both sides and the raised vent overlaps the countertop 
in back. It is also possible, if the cabinets are deep enough, to self 
rim the front of the range into the cabinet face immediately behind the 
control panel and door trim or behind the side panels (see side views 
on following page). The rear range trim will partially cover the front of 
the raised vent chassis in back.
MODEL DR30DI/ERV3015 COUNTERTOP SELf-RIMMED 
ONLy, 3 1/4 INCh SIDE PANELS NOT REMOVED
Cabinet tolerances: -1/16”, (+1.6 mm) -0
Cabinet face
Countertop
Range trim resting
on countertop
Back of
control
panel
DR30DI range
3/8” min. (1.0 cm)
flat countertop
overhang required 
behind cutout
3 1/4 inch
side panel
ERV3015
raised vent
3/8” min. (1.0 cm) space
required behind ERV3015
chassis to clear stiffener
H
rear wall recommended
Non-combustible
countertop opening
cabinet opening
below countertop
29 1/4” (74 3 cm)
27 1/2” (69.9 cm)
30” (76.2 cm)
2 9/16” 
(6.5 cm)
10” min.
(25.4 cm)
both sides
Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm) 
Notch countertop
overhang to width of
cabinets
3/8” min. (1.0 cm)
countertop
overhang
raised vent  opening
H
Combustible side
wall above range
below countertop
To cabinet face
To countertop
 front
J K
TOP VIEw
SIDE VIEw
A
A
B C