5.7
30” Wide, Epicure
®
All Gas Range
ER30G, ER30GI
12 1/2”
(318 mm)
to
14 5/8”
(371 mm)
2 5/8”
(67 mm)
CL
CL
10” (254mm)
10” (254mm)
12” (305mm)
2 1/2”
(64mm)
3 1/2”
(89mm)
1” (25mm)
bAck Of RANGE
UtILIty cLEARANcE bEhIND RANGE
GAS SuppLY pRESSuRE REQuIREmEnTS
Gas
Type
manifold
pressure* (WC)
min. Gas Supply
pressure (WC)
max. Input
pressure
Natural
5”
6”
1/2 p.s.i.
LP
10”
11”
1/2 p.s.i.
ImpoRTAnT: The information above is for reference only. If the
above data does not agree with the product data label, use the
data on the product data label on top of the kick plate below the
door (remove the door according to the installation instructions to
view it).
The gas connection is located on the back of the unit as shown.
The gas connection is located on the back of the unit as shown.
Use a 1/2" male NPT to connect to the regulator.