Viking VMOR205SS Installationsanweisungen

Seite von 16
1
F20380
TINSEB427MRR0
Please read all instructions thoroughly before installing the Convection Microwave Hood. Two people are recom-
mended to install this product.
If a new electrical outlet is required, its installation should be completed by a qualified electrician before the 
Convection Microwave Hood is installed. See 3 ELECTRICAL GROUNDING INSTRUCTIONS on page 2.
1 MOUNTING SPACE
This Convection Microwave Hood requires a mounting 
space on a wall as shown in Figure 1. It is designed to 
be used with standard 12-inch wall cabinets.
For proper installation and servicing, a 2-inch space is 
necessary between the top of the range backguard and 
the bottom of the Convection Microwave Hood.
2  WALL CONSTRUCTION
This Convection Microwave Hood should be mounted 
against and supported by a flat vertical wall. The wall 
must  be  flat  for  proper  installation.  If  the  wall  is  not 
flat, use spacers to fill in the gaps. Wall construction 
should be a minimum of 2” x 4” wood studding and 
3/8” or more thick dry wall or plaster/lath. The mount-
ing surfaces must be capable of supporting a weight of 
110 pounds—the oven and contents—AND the weight 
of all items which would normally be stored in the top 
cabinet above the unit.
The unit should be attached to a minimum of one 2” x 
4” wall stud or two 2" x 3" wall studs.
To find the location of the studs, one of the following 
methods may be used:
A. Use a stud finder, a magnetic device which locates 
the nails in the stud.
B.  Use  a  hammer  to  tap  lightly  across  the  mounting 
surface to find a solid sound. This will indicate stud 
location. 
The center of the stud can be located by probing the 
wall with a small nail to find the edges of the stud and 
then placing a mark halfway between the edges. The 
center of any adjacent studs will normally be 16” or 24” 
to either side of this mark.
CONVECTION MICROWAVE HOOD
INSTALLATION INSTRUCTIONS
Figure 1
Backguard
At least 2"
15.5"
30"
12"
30" or more 
from cooking 
surface
66" or more 
from floor