ALLURE
®
  QS2 SERIES
RANGE HOOD
PREPARE THE HOOD 
(Continued)
4
Remove Damper/Duct Connector from inside the hood.
Set connector aside - with mounting screws and parts bag.
3
Remove Teflon
®
-coated bottom cover from hood. Set
cover and mounting screws aside.
5
Remove either top or back wiring knockout and install
approved Electrical Cable Clamp.
PREPARE THE HOOD 
(Continued)
6
Remove appropriate Duct Knockout(s) from top or back of
hood.
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Horizontal Discharge)
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Vertical & for 7” Round
Discharge)
SEMI-CIRCULAR
DUCT KNOCKOUT
(Remove for 7” Round
Discharge)
DAMPER/
DUCT
CONNECTOR
ELECTRICAL
CABLE CLAMP
NOTE
If hood is to be installed Non-Ducted:
Purchase a set of (2) Non-Ducted Filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
Skip to “CONNECT WIRING” section on page 4.
TEFLON
®
-
COATED
BOTTOM
COVER
(Held in
place with
2 screws)
7
Horizontal Discharge Only: Remove the Plate in front of the
horizontal discharge knockout. Cut the Ties, lift plate out, and
discard plate. DO NOT REMOVE the Metal Strip held in place
with two Screws.
TIES