Specifications  
subject to change.
Glass Canopy Wall-Mount Hood
FHWC3660L S    
36" Stainless Steel
Glass Canopy Wall-Mount Hood Specifications
 Product Shipping Weight (approx.) – 54 Lbs.
 Wall-Mount Installation
 Ventilation  system  is  preset  to  exhaust  air  outside.  If  outside   
ducting  is  not  possible,  optional  Duct-Free  Recirculation  Kit   
(PN #  FHWRKT60LS)  is  available  to  convert  ventilation  to  allow  air   
to  recirculate  inside.  (Refer  to  Ducted  Option  Specifications  for 
outside  ventilation.)
 Sones Rating – 6.5
 
Voltage Rating – 120V / 60 Hz / 15 Amps
 Connected Load (kW Rating) @ 120 Volts = 0.516 kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded  
for safe operation.)
 Amps @ 120 Volts = 4 Amps
 Always consult local and national electric codes. Check local building 
codes for installation requirements, as they may vary per locale.
 Minimum installation height allowed from bottom of hood to standard 
36"-high electric or gas cooking surface is 26" - 35". (NOT more than 
32" recommended.) For detailed instructions regarding install heights 
in 8', 9' and 10' ceiling applications, refer to installation guide on web.
 To prepare mounting surface, adequate structure and support must 
be provided, capable of supporting 100 lbs.
Ducted Option Specifications
 For outside ventilation.
 Exhaust Duct Required – 6" round
 For most efficient airflow exhaust, use a straight run or as few elbows  
as possible.
 Use metallic flex ducting only to connect rigid duct directly to 
transitions (if allowed by code).
 Thermal breaks such as short section of nonmetallic duct, should  
be used in areas of extreme cold.
 Cold weather installations should have additional backdraft damper 
installed.
 Refer to installation instructions on web for detailed exhaust duct  
preparation and converting vent blower system for recirculating inside.
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
Optional Accessories
 Duct-Free Recirculation Kit – (PN # FHWRKT60LS).
 10' Flue Extension Kit – (PN # FHW10X60LS).