INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools needed
 
Parts supplied
Check that all parts are included. 
LP/Natural Gas Conversion Kit (located on back of range near 
lower side)
Burner grates
Burner caps
Oven racks
2 - #12 x 1
⁵⁄₈" screws (for mounting anti-tip bracket)
Anti-tip bracket (taped inside upper oven with package 
containing literature)
Anti-tip bracket must be securely mounted to the back wall or 
floor. Thickness of flooring may require longer screws to 
anchor bracket to subfloor. Longer screws are available from 
your local hardware store.
Parts needed
Check local codes and consult gas supplier. Check existing gas 
supply and electrical supply. See “Electrical Requirements” and 
“Gas Supply Requirements” sections. 
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Do 
not obstruct flow of combustion and ventilation air. 
It is the installer’s responsibility to comply with installation 
clearances specified on the rating number plate. The rating 
number plate is located behind the control panel.
The range should be located for convenient use in the 
kitchen.
Recessed installations must provide complete enclosure of 
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
or microwave hood combination that projects horizontally a 
minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
All openings in the wall or floor where range is to be installed 
must be sealed.
Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip 
Bracket” section.
Grounded electrical supply is required. See “Electrical 
Requirements” section. 
Proper gas supply connection must be available. See “Gas 
Supply Requirements” section.
Contact a qualified floor covering installer to check that the 
floor covering can withstand at least 200°F (93°C). 
Use an insulated pad or ¼" (0.64 cm) plywood under range if 
installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage. This oven 
has been designed in accordance with the requirements of UL 
and CSA International and complies with the maximum allowable 
wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 24, HUD Part 280). When such standard is not 
applicable, use the Standard for Manufactured Home 
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the 
current standards CAN/CSA-A240-latest edition, or with local 
codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be 
secured to the floor during transit. Any method of securing 
the range is adequate as long as it conforms to the standards 
listed above.
Tape measure
Phillips screwdriver
Torx
®†
 T20
®†
 screwdriver
Flat-blade screwdriver
¹⁄₈" flat-blade screwdriver
Level
Hand or electric drill
Wrench or pliers
Pipe wrench
¹⁵⁄₁₆" combination wrench
¹⁄₈" (3.2 mm) drill bit
Marker or pencil
Pipe-joint compound 
resistant to LP gas
Noncorrosive leak-detection 
solution
For LP/Natural Gas 
Conversions
½" combination wrench
⁹⁄₃₂" (7.0 mm) nut driver 
Masking tape