STEP #5
Electrical Connection
Before proceeding further, verify that the power
supply is disconnected. Verify that the
appropriate electrical supply requirements have
been met. Please refer to the table on page
5 for appropriate electrical requirements. The
cooktop is supplied with either a 15 amp US
cord for 120V units, or flying leads for 240V
units. The 120V 15 amp US cord plugs into
any standard household 120V outlet. The
240V conduit consists of three insulated wires.
There are two insulated hot lead conductors
(red and black) and one insulated ground
conductor (green).
Attach conductor wires to residence wiring in
accordance with national, state and local
electric codes.
SilKEN® INDUCTION COOKTOP
# 8 X 1/4" SCREW
# 6 X 1 1/4" S/S SCREW
MOUNTING BRACKET
COUNTER SURFACE
Fig. C
STEP #6
Final Preparations Prior to Use
Remove the plastic film from the cooktop. Clean
the cooktop before you use it for the first time. A
thorough cleaning with a recommended cooktop
cleaner (Cerama Bryte Ceramic Cooktop
Cleaner) will provide a clean, shiny coating on
the cooktop surface.
The next section of the manual covers cooktop
use, maintenance and service information.
Please keep these instructions with the
KENYON cooktop for future reference.
Name Plate
Label Location
Warning - Grounding
The entire appliance must be grounded at all times when the
electrical power supply is on. Do not ground the appliance with the
neutral house supply wire (white). A separate ground must be used.
!
8