Whirlpool G7CE3635X Installationsanweisungen

Seite von 16
2
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools needed
Parts supplied
Parts needed
A UL listed or CSA approved connector for ½" (1.3 cm) 
diameter conduit
UL listed wire connectors
Check local codes. Check existing electrical supply. See the 
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. 
When installing cooktop, use minimum dimensions given.
To eliminate the risk of burns or fire by reaching over the 
heated surface units, cabinet storage space located above 
the surface units should be avoided. If cabinet storage is to 
be provided, the risk can be reduced by installing a range 
hood that projects horizontally a minimum of 5" (12.7 cm) 
beyond the bottom of the cabinets.
The cooktop must be a specified cooktop that is approved to 
be installed either alone or over an undercounter built-in 
oven. Check the cooktop base for an approved installation 
label. If you do not find this label, contact your dealer to 
confirm that your cooktop is approved.
The cooktop must be installed in a level countertop.
Ovens approved for this type of installation will have an 
approval label located on the top of the oven. If you do not 
find this label, contact your dealer to confirm that your oven is 
approved. Refer to oven manufacturer’s Installation 
Instructions for approval for built-in undercounter use and 
proper cutout dimensions.
The cooktop should be installed away from strong draft 
areas, such as windows, doors, fans or strong heating vents. 
The cooktop should be located for convenient use in the 
kitchen.
Use the countertop opening dimensions that are given with 
these Installation Instructions. Given dimensions are 
minimum clearances and provide 0" (0 cm) clearance.
Grounded electrical supply is required. See “Electrical 
Requirements” section.
IMPORTANT: To avoid damage, check with your builder or 
cabinet supplier to make sure that the materials used will not 
discolor, delaminate or sustain other damage.
Product Dimensions
Tape measure
¼" (6.35 mm) nut driver
Marker or pencil
Pliers
Flat-blade screwdriver
Foam strip roll
Clamping brackets (2)
2½" (6.4 cm) clamping 
screws (2)
A. 21¾" (55.2 cm)
B. 30" (76.2 cm) models - 30
¹³⁄₁₆
" (78.4 cm)
36" (91.4 cm) models - 36
⁵⁄₁₆
" (92.3 cm)
C. 3¾" (9.5 cm)
C
A
B