Connect Vent
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (102 mm) clamp.
2. Move dryer into final position. Do not crush or kink vent,
and remove any excess flexible vent to improve airflow.
Make sure dryer is level.
Complete Installation
1. With dryer in final position, place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
2. Plug in dryer or reconnect power.
3. Check dryer operation:
Insert coins. Select a cycle. Using the WHITES cycle, let the
dryer run for at least five minutes. Dryer will stop when time
is used up.
NOTE: Dryer door must be closed for dryer to operate.
When door is open, dryer stops, but timer continues to run.
To restart dryer, close door and reselect a cycle.
4. If drying time is too long, make sure that the lint screen is
clean, and that there are no obstacles to airflow in the dryer
vent system.
5. Now start the dryer and allow it to complete a full cycle
to make sure it is working properly.
Optional,
3-wire connection:
Use for direct wire or power supply cord
where local codes do not permit
connecting cabinet-ground conductor
to neutral wire.
1. Remove center, silver-colored terminal
block screw.
2. Remove neutral ground wire from
external ground conductor screw.
Connect neutral ground wire and the
neutral wire (white or center wire) of
power supply cord/cable under center,
silver-colored terminal block screw.
Tighten screw.
3. Connect the other wires to outer terminal
block screws. Tighten screws.
4. Tighten strain relief screws.
5. Connect a separate copper ground wire
from the external ground conductor
screw to an adequate ground.
6. Insert tab of terminal block cover into
slot of dryer rear panel. Secure cover
with holddown screw.
C
B
A
D
E
F
A. External ground conductor screw
B. Center, silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL listed strain relief
F. Grounding path determined by a qualified
electrician
WARNING