Dacor DTO230W Designanleitung
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
DTO, DTOV
Document # PG01-014
Revised 06/05/14 Page 1/2
Distinctive
®
27” and 30” Wide
Double Wall Ovens
Model
(A)
Overall
Width
(B)
Chassis
Width
(C) Overall
Height
(D)
Chassis
Height
(E) Control
Panel
Overlay
DTO[V]227
26 7/8”
(68.3 cm)
25 3/8”
(64.5 cm)
50 1/8”
(127.3 cm)
49”
(124.5 cm)
1 1/8”
(2.9 cm)
DTO[V]230
29 7/8”
(75.9 cm)
28 3/8”
(72.1 cm)
50 1/8”
(127.3 cm)
49”
(124.5 cm)
1 1/8”
(2.9 cm)
(F) Utility
Cutout Width
(G) Utility
Cutout Height
(H) Utility
Cutout Depth
(J) Control
Panel Depth
(K) Chassis
Depth
6 1/2”
(16.5 cm)
5”
(12.7 cm)
7 7/8”
(20.0 cm)
1 1/4”
(3.2 cm)
23 1/2”
(59.7 cm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
21 7/8”
(55.6) cm
C
A
Conduit:
60” (152 cm)
long
D
J
B
H
G
F
Top of
chassis
Utility
cutout
K
Control panel
side view
Control panel
front
Top of
chassis
E
3 1/2”
(8.9 cm)
3 3/16”
(8.1 cm)
1 1/8”
(2.9 cm)
1 1/8”
(2.9 cm)
1 1/8”
(2.9 cm)
Handle Dimensions
Epicure
Millennia
(Order kit #AROVH30S)
Flush
ELECTRICAL SPECIFICATIONS
Model
Dedicated Circuit
Requirements
Total Connected Load
DTO[V]227
240 Vac 60 Hz., 4-wire,*
40 Amp.
240 Vac 60 Hz,
26.2 Amp., 6.4 kW
DTO[V]230
240 Vac 60 Hz., 4-wire,*
40 Amp.
240 Vac 60 Hz,
26.6 Amp., 6.4 kW
* Two 120 Vac hot (L1 and L2), one neutral, one ground
The above specifications are for reference only. See the appliance data
The above specifications are for reference only. See the appliance data
plate for exact specifications.