Whirlpool WEG730H0DS Spezifikationenblatt

Seite von 4
30" (76.2 cm) Slide-in Gas Range
PRODUCT MODEL NUMBERS
WEG730H0D          WEG760H0D
GAS SUPPLY REQUIREMENTS
Gas supply line:
Provide a gas supply line of 
3
4
" (1.9 cm) rigid pipe to the
range location. A smaller size pipe on longer runs may
result in insufficient gas supply. With LP gas, piping or
tubing size can be 
1
2
" (1.3 cm) minimum. Usually, LP gas
suppliers determine the size and materials used in the
system.
NOTE: Pipe-joint compounds that resist the action of LP
gas must be used. Do not use TEFLON
®†
 tape.
Flexible metal appliance connector: 
If local codes permit, a new CSA design-certified, 4 to
5 ft (122 to 152.4 cm) long, 
1
2
" (1.3 cm) or 
3
4
" (1.9 cm)
I.D., flexible metal appliance connector may be used for
connecting range to the gas supply line.
1
2
" (1.3 cm) male pipe thread is needed for connection
to the female pipe threads of the inlet to the appliance
pressure regulator.
Do not kink or damage the flexible metal tubing when
moving the range.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff
valve. This valve should be located in the same room but
external to the range opening, such as an adjacent cabinet.
It should be in a location that allows ease of opening and
closing. Do not block access to shutoff valve. The valve is
for turning on or shutting off gas to the range.
A.   Gas supply line
B.   Shutoff valve “open” position
C.   To range
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be 
used. The inlet pressure to the regulator should be as follows 
for proper operation:
Natural gas:
Minimum pressure: 5" WCP
Maximum pressure: 14" WCP
LP gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet 
pressure.
PRODUCT DIMENSIONS
This manual covers several models. Your model may appear 
different from the models depicted. Dimensions given are 
maximum dimensions across all models.
A.   1 
3
16
" (3.0 cm) height from
      cooktop to top of vent
B.   29 
7
8
" (75.9 cm)
C.   Model/serial number plate
      (located behind the oven door on
      the top right-hand side of the
      oven frame)
D.   36" (91.4 cm) height to top of
      cooktop edge with leveling legs
      screwed all the way in*
E.   28 
5
16
" (71.9 cm) max.
      depth from front of console
      to back of range.
F.    28 
7
8
" (73.3 cm) max. depth
      from handle to back of
      range.
IMPORTANT: Range must be level after installation. Follow the 
instructions in the “Level Range” section. Using the cooktop as 
a reference for leveling the range is not recommended.
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
Type of Gas 
Natural gas:
This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial rating plate located
behind the control panel has information on the types
of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas
supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No 
attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See “Gas 
Conversions” section. 
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and 
Company.
Page 1 of 2
Ref. W10665256E
08/15
B
D
A
F
E
C
A
B
C