DCS RGV486G Spezifikationenblatt

Seite von 2
Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
dcsappliances.com 
dcsappliances.ca
P. 888-936-7872
Product Dimensions (inches)
RGU-48 
RGV-48
RGU-36 
RGV-36
RGU-30 
RGV-30
A
Width of product
47 – 
7
/
8
"
35 – 
7
/
8
"
29 – 
7
/
8
"
B
Height of full backguard
26 – 
1
/
2
"
26 – 
1
/
2
"
26 – 
1
/
2
"
C
Height of standard backguard
11 – 13⁄32"
11 – 13⁄32"
11 – 13⁄32"
D
Height of integral island trim
3 – 
1
/
2
"
3  – 
1
/
2
"
3  – 
1
/
2
"
E
Height of product (from floor to cooktop trim, excluding grates  
and island trim)
min. 35 – 
3
/
4
max. 36 – 
3
/
4
"
min. 35 – 
3
/
4
max. 36 – 
3
/
4
"
min. 35 – 
3
/
4
max. 36 – 
3
/
4
"
F
Maximum depth from wall to front of product (including handle)
30 – 
1
/
4
"
30 – 
1
/
4
"
30 – 
1
/
4
"
G
Maximum depth from wall to front of product with door open
46 – 
11
/
16
"
46 – 
11
/
16
"
46 – 
11
/
16
"
H
Maximum depth from wall to front of product (excl. handle and knobs)
29"
29"
29"
I
Depth of standard backguard
13⁄16"
13⁄16"
13⁄16"
I
1
Depth of full backguard
1 – 5⁄16"
1 – 5⁄16"
1 – 5⁄16"
J
Depth from wall to front of range side panel
25"
25"
25"
K
Depth of product from wall to oven door front (excl. handle)
27 – 
1
/
2
"
27 – 
1
/
2
"
27 – 
1
/
2
"
Gas Ranges Product Dimensions
RGU-48, RGU-36, RGU-30 
RGV-48, RGV-36, RGV-30
  
  
A
A
Hood
Standard Installation: 
using the appropriate range mount
Standard backguard model: BGRU2-1548, 
BGRU2-1536, BGRU2-1530
Full Backguard Installation: 
using the appropriate wall mount Full
backguard model: BGRU-3048, 
BGRU-3036, or BGRU-3030
Island Installation:
using the integral island trim only
RGU-48, RGV48
RGU-36, RGV-36
RGU-30, RGV-30
A
B
C
D
D
D
E
E
F
F
G
G
H
I
I
1
H
J
K
Hood
Hood
51" Min. to 
combustibles
0" Clearance
0" Clearance
0" Clearance
51" Min. to 
combustibles
51" Min. to 
combustibles
12" Min. to  
combustibles ,  
     without backguard
 As defined in the "National Fuel Gas Code" (ANSI Z223.1, latest edition).
The horizontal surfaces of the cooktop trim must not be below countertop level.
Important!
If using the island trim only, a 12" clearance is 
required between the back of the range and a 
combustible surface (above the cooking surface). 
If the clearance is less than 12", the back wall must 
be non-combustible and made of heat-resistant 
material.